List of Subjects for 28 CFR Part 36
-
608.2.3 Alternate Roll-In Type Shower Compartments
A 36 inch (915 mm) wide minimum entry shall be provided at one end of the long side of the compartment....
-
LULA Elevator Dimensions
The guidelines specify that LULA elevator cars be at least 42 inches wide and 54 inches deep with a door on the narrow end providing at least 32 inches clear width (408.4.1)....
-
§8.27(a)
To this end, when an accessible unit becomes vacant, the owner or manager before offering such units to a non-handicapped applicant shall offer such unit:...
-
3. Measuring Door Openings
Place the end of the tape measure on the side of the door frame next to the clear opening (see below). Stretch the tape across the door opening to the face of the door....
-
Question 11
Should the replacement of inaccessible medical equipment or furniture be triggered only by the end of the useful life of the equipment or furniture?...
-
304.3.2 T-Shaped Space
The space shall be permitted to include knee and toe clearance complying with 306 only at the end of either the base or one arm....
-
R212.6 Benches
The clear space shall be located either at one end of the bench or shall not overlap the area within 460 mm (1.5 ft) from the front edge of the bench....
-
304.3.2 T-Shaped Space
The space shall be permitted to include knee and toe clearance complying with 306 only at the end of either the base or one arm....
-
28 CFR Part 36, Appendix B: Preamble to Regulation on Nondiscrimination on the Basis of Disability by Public Accommodations and in Commercial Facilities (1991 ADA Title III Regulations Preamble)
nondiscrimination on the basis of disability by public accommodations and in commercial facilities beginning at the heading "Section-by-Section Analysis and Response to Comments'' and ending...
-
11B-502.6.4.1
a maximum of 6 inches (152 mm) from the centerline of the parking space, its sides parallel to the length of the parking space and its lower corner at, or lower side aligned with, the end...
-
11B-610.2 Bathtub seats
Permanent seats at the head end of the bathtub shall be 15 inches (381 mm) deep minimum and shall extend from the back wall to or beyond the outer edge of the bathtub....
-
610.2 Bathtub Seats
Permanent seats at the head end of the bathtub shall be 15 inches (380 mm) deep minimum and shall extend from the back wall to or beyond the outer edge of the bathtub....
-
304.3.2 T-Shaped Space
The space shall be permitted to include knee and toe clearance complying with 306 only at the end of either the base or one arm....
- BEA Inc. LPR36 Series 36" Low Profile Push Plate
-
3. Folding Seat
Do the roll-in showers have a securely fastened folding seat at 17"-19" above the floor onto which persons who use wheelchairs may transfer to shower?...
-
R409.4 Height
Top of gripping surfaces of handrails shall be 865 mm (2.8 ft) minimum and 965 mm (3.2 ft) maximum vertically above walking surfaces, ramp surfaces, and stair nosings....
-
Boating facilities. (Section-by-Section Analysis)
If gangways (only one end of route is attached to land) and floating piers (neither end is attached to land) are involved, a number of exceptions are provided from the general standards...
-
Boating facilities. (Section-by-Section Analysis)
If gangways (only one end of route is attached to land) and floating piers (neither end is attached to land) are involved, a number of exceptions are provided from the general standards...
-
502.3 Accessibility Services (Section-by-Section Analysis)
A documented set of accessibility services is important to end-users because, without them, developers are likely to provide inconsistent access to assistive technology, thereby leaving...
-
11B-1009.3.1 Sloped entries
Exception: Where sloped entries are provided, the surfaces shall not be required to be slip resistant....
-
11B-1009.3.1 Sloped entries
Exception: Where sloped entries are provided, the surfaces shall not be required to be slip resistant....
-
11B-1003.3.2 Boarding pier clearances
At high water, the entire chain is floating and a transition plate connects the first float to the surface of the launch ramp....
-
1003.3.2 Boarding Pier Clearances