[See subsections ...]
Search Results "Clear Deck Space"
Commonly Searched Documents
-
4.2 Space Allowance and Reach Ranges
-
4.2 SPACE ALLOWANCE AND REACH RANGES
[See subsections ...]
-
Comparison of Single-User Toilet Room Layouts: 2A, 2B, and 2C
The in-swinging door increases overall room size because it cannot swing over the required clear floor space at any accessible fixture, (see section 4.22.2 of the 1991 Standards)....
-
Comparison of Single-User Toilet Room Layouts: 1A, 1B, and 1C
A lavatory with knee space can overlap the clear floor space required for the water closet provided that at least 36 inches of clearance is maintained between the side wall next to the water...
- International Building Code® (IBC®)
- AD Systems’ Patient Restrooms
-
904.4.2 Forward Approach
Knee and toe space complying with 306 shall be provided under the counter. A clear floor or ground space complying with 305 shall be positioned for a forward approach to the counter....
-
Accessible Route
A continuous unobstructed path connecting all accessible elements and spaces of a building or facility....
-
4.34.5.5(1) Size and clearances
Shower stall size and clear floor space shall comply with either Fig. 35(a) or (b). The shower stall in Fig. 35(a) shall be 36 in by 36 in (915 mm by 915 mm)....
-
The carrier must designate priority stowage space for at least one wheelchair in the closet or other stowage area
other approved stowage area for passengers’ carry-on items of sufficient size to accommodate a folding, collapsible, or break-down wheelchair, the carrier must designate priority stowage space...
-
Parking Meters and Parking Pay Stations (R309.5) (Section-by-Section Analysis)
Parking Meters and Parking Pay Stations (R309.5) (Section-by-Section Analysis) Operable parts of parking meters and parking pay stations that serve accessible on-street parking spaces...
-
§382.57(c)(7)(i) Visibility
The display screen must be visible from a point located 40 inches (1015 mm) above the center of the clear floor space in front of the automated kiosk....
-
R304.5.1 Width
The clear width of curb ramp runs (excluding any flared sides), blended transitions, and turning spaces shall be 1.2 m (4.0 ft) minimum....
-
§27.71(k)(7)(i) Visibility.
The display screen must be visible from a point located 40 inches (1015 mm) above the center of the clear floor space in front of the automated kiosk....
-
§ 382.57(c)(7)(i) Visibility
The display screen must be visible from a point located 40 inches (1015 mm) above the center of the clear floor space in front of the automated kiosk....
-
§ 27.71(k)(7)(i) Visibility
The display screen must be visible from a point located 40 inches (1015 mm) above the center of the clear floor space in front of the automated kiosk....
-
305.7 Maneuvering Clearance
Where a clear floor or ground space is located in an alcove or otherwise confined on all or part of three sides, additional maneuvering clearance shall be provided in accordance with 305.7.1...
-
11B-707.7.1 Visibility
The display screen shall be visible from a point located 40 inches (1016 mm) above the center of the clear floor space in front of the machine....
-
Technical Memorandum TM 2012-07 Press Boxes
Therefore, in the sense that the text implies, the aggregate area of a press box shall include toilet rooms, corridors, and any other areas, elements, and spaces located within the press...
-
308.3.1 Unobstructed
Where a clear floor or ground space allows a parallel approach to an element and the side reach is unobstructed, the high side reach shall be 48 inches (1220 mm) maximum and the low side...
-
406.6 Diagonal Curb Ramps
The bottom of diagonal curb ramps shall have a clear space 48 inches (1220 mm) minimum outside active traffic lanes of the roadway....
-
1133A.2, Item 1
A clear floor space at least 30 inches (762 mm) by 48 inches (1219 mm) that allows a parallel approach by a person in a wheelchair shall be provided at the range or cooktop....
-
11B-802.5 Semi-ambulant seats
Semi-ambulant seats shall provide at least 24 inches (610 mm) clear leg space between the front of the seat to the nearest obstruction or to the back of the seat immediately in front....
-
§ 36.406(d)(1)
(1) In sleeping rooms with more than 25 beds covered by this section, a minimum of 5% of the beds shall have clear floor space complying with section 806.2.3 of the 2010 Standards....