Access aisles are required to be nearly level in all directions to provide a surface for wheelchair transfer to and from vehicles. The exception allows sufficient slope for drainage....
Search Results "Assurances from Contractors"
-
11B-502.4 Floor or ground surfaces
-
Clearance in Base (M301.4.1 and M302.4.1)
M301.4.1 and M302.4.1 would require the clearance in the base to be 44 inches wide minimum, 6 inches high minimum measured from the floor, and 36 inches deep minimum measured from the edge...
-
B.
., providing fixed route bus service that people with disabilities can use to move among stops on the system, providing complementary paratransit service that gets eligible riders from their...
-
§ 37.187(b)
by a small mixed-service operator under §37.191), and the passenger has purchased the ticket or made the reservation for the interline trip only 8 hours before Operator Y's bus leaves from...
-
Category 1 Eligibility
This eligibility category includes people who cannot board, ride, or disembark from an accessible vehicle “without the assistance of another individual.”...
-
11B-707.4 Privacy
Speech output users can benefit from an option to render the visible screen blank, thereby affording them greater personal security and privacy....
-
11B-502.4 Floor or ground surfaces
Access aisles are required to be nearly level in all directions to provide a surface for wheelchair transfer to and from vehicles. The exception allows sufficient slope for drainage....
-
11B-608.2.1 Transfer type shower compartments
Clearance of 36 inches (914 mm) wide minimum by 48 inches (1219 mm) long minimum measured from the control wall shall be provided....
-
11B-707.4 Privacy
Speech output users can benefit from an option to render the visible screen blank, thereby affording them greater personal security and privacy. ◼ ETA Editor's Note The Department of...
-
810.5.3 Platform and Vehicle Floor Coordination
EXCEPTION: Where vehicles are boarded from sidewalks or street-level, low-level platforms shall be permitted to be less than 8 inches (205 mm)....
-
11B-603.6 Guest room toilet and bathing rooms
.◼ ETA Editor's Note: From DSA's "Summary of New and Amended 2025 California Building Code (CBC) Regulations for Accessibility in the Triennial Code Cycle: "Language was amended...
-
1009.9 Signage
Signage indicating special accessibility provisions shall be provided as shown: Each door providing access to an area of refuge from an adjacent floor area shall be identified by a...
-
Gripping Surface: ADA Standard Section 505.6
Section 505.6 covers the current ADA Standards for the handrail gripping surface.
-
11B-505.6 Gripping surface
People with disabilities, older people, and others benefit from continuous gripping surfaces that permit users to reach the fingers outward or downward to grasp the handrail, particularly...
-
11B-504.5 Nosings
Risers shall be permitted to slope under the tread at an angle of 30 degrees maximum from vertical....
-
11B-504.5 Nosings
Risers shall be permitted to slope under the tread at an angle of 30 degrees maximum from vertical....
-
11B-213.3.6 Bathing facilities
Where two or more accessible showers are provided within the same functional area, at least one shower shall be opposite hand from the other or others (that is, one left-hand controls versus...
-
11B-213.3.6 Bathing facilities
Where two or more accessible showers are provided within the same functional area, at least one shower shall be opposite hand from the other or others (that is, one left-hand controls versus...
-
1009.9 Signage
Signage indicating special accessibility provisions shall be provided as shown: Each door providing access to an area of refuge from an adjacent floor area shall be identified by a...
-
11B-505.6 Gripping surface
People with disabilities, older people, and others benefit from continuous gripping surfaces that permit users to reach the fingers outward or downward to grasp the handrail, particularly...
- Part 14- Save, Transfer & Restore a Backup Using iTunes for Windows
- Redi Free® with Redi Base® Shower Pans
- Redi Free® with Redi Trench® Shower Pans
-
General
The 1991 Standards exempt facilities equipped with a supervised automatic sprinkler system from providing areas of rescue assistance, and also exempt alterations to existing facilities from...