Provide at least one mode that does not require user fine motor control or simultaneous actions....
Search Results "Multi-User Toilet Room"
Commonly Searched Documents
-
§1193.41(e) Operable with limited manual dexterity
-
§ 37.165(d)
(d) The entity may not deny transportation to a wheelchair or its user on the ground that the device cannot be secured or restrained satisfactorily by the vehicle's securement system....
-
§ 38.79(a)
(a) Floor surfaces on aisles, step treads, places for standees, and areas where wheelchair and mobility aid users are to be accommodated shall be slip-resistant....
-
§ 38.99(a)
(a) Floor surfaces on aisles, step treads, places for standees, and areas where wheelchair and mobility aid users are to be accommodated shall be slip-resistant...
- American Specialties Roval™ Collection Surface Mounted Paper Towel Dispenser 20210
- Hager Companies 3600 Series Lever
-
36 CFR Part 1190, Proposed Accessibility Guidelines for Pedestrian Facilities in the Public Right-of-Way; Shared Use Paths (SNPRM)
Shared use paths are multi-use paths designed primarily for use by bicyclists and pedestrians, including pedestrians with disabilities, for transportation and recreation purposes....
-
1023.9 Stairway identification signs
"Floor Identification Signs" are for routine wayfinding use by vision-impaired persons and others who use the stairs, and these are required at all enclosed stairways of multi-story buildings...
-
Place of Public Accommodation
Except for an establishment located within a facility that contains not more than five rooms for rent or hire and that actually is occupied by the proprietor of the establishment as the...
- Bobrick ClassicSeries Surface Mounted Seat-Cover Dispenser B-221
-
2010 ADA Standards for Accessible Design
For example there are no questions about patient rooms in hospitals or guest rooms in hotels. Consult the 2010 Standards for situations not covered in the checklist....
-
4.3.10* EGRESS
Where fire code provisions require more than one means of egress from any space or room, then more than one accessible means of egress shall also be provided for handicapped people....
-
11B-404.2.4 Maneuvering clearances
[2010 ADAS] EXCEPTION: Entry doors to hospital patient rooms shall not be required to provide the clearance beyond the latch side of the door....
-
11B-404.2.4 Maneuvering clearances
[2010 ADA Standards] EXCEPTION: Entry doors to hospital patient rooms shall not be required to provide the clearance beyond the latch side of the door....
-
11B-903.1 General
This section provides the technical provisions for benches required to comply with Division 2 Scoping Requirements -- those in saunas, steam rooms, dressing, fitting and locker rooms, holding...
-
302.3 Without Perception of Color (Section-by-Section Analysis)
302.3 Without Perception of Color (Section-by-Section Analysis) This section proposes to add a new functional performance criterion for users with color blindness to better map to technical...
-
§382.57(c)(5)(i) Speech output enabled
Operating instructions and orientation, visible transaction prompts, user input verification, error messages, and all other visual information for full use must be accessible to and independently...
-
§27.71(k)(5)(i) Speech output enabled.
Operating instructions and orientation, visible transaction prompts, user input verification, error messages, and all other visual information for full use must be accessible to and independently...
-
§ 382.57(c)(5)(i) Speech output enabled
Operating instructions and orientation, visible transaction prompts, user input verification, error messages, and all other visual information for full use must be accessible to and independently...
-
Tool-tips on images
The information that users need to know should not be ‘hidden’ in a tool-tip....
-
§ 27.71(k)(5)(i) Speech output enabled
Operating instructions and orientation, visible transaction prompts, user input verification, error messages, and all other visual information for full use must be accessible to and independently...
-
A4.2.1(1) Space Requirements for Wheelchairs
Most wheelchair users need a 30 in (760 mm) clear opening width for doorways, gates, and the like, when the latter are entered head-on....
-
Guiding Principles
The use of touch and tactile exhibit elements should be recognized as a part of a multi-modal learning strategy....
-
Stopping Distance
Table 15 shows the braking distance, i.e. the distance traveled from the time that the user initiated braking to the time that the user came to a complete stop, for user groups with five...