213.3.1 Toilet compartments Corrects drafting error in prior code adoption to require that the fixture count for determining when additional accessible...
Search Results "DSA-AC: California Division of the State Architect – Access Compliance"
-
11B-213.3.1 Toilet compartments
-
Do facilities in remote locations have to be accessible?
If the Forest Service builds a facility, even in remote areas or areas that are difficult to access (including wilderness), the facility must be accessible, with few exceptions....
-
Public Education
Within ninety (90) days of the effective date of the Agreement, the Supervisor shall submit the proposed public educational materials for review and approval to the United States....
-
5. Site Constraints, Technical Infeasibility, and Unusually Expensive Remediation
Work on difficult sites may be postponed if there is an alternative accessible route within no more than 200 feet, to the maximum extent feasible. ...
-
11B-411.2.1.3.1 Keypad call console arrangement
The accessibility function button shall be located directly below the keypad at a height of 36 inches (914 mm) to 42 inches (1067 mm) above the finish floor....
-
11B-411.2.1.3.1 Keypad call console arrangement
The accessibility function button shall be located directly below the keypad at a height of 36 inches (914 mm) to 42 inches (1067 mm) above the finish floor....
-
11B-411.2.1.3.1 Keypad call console arrangement
The accessibility function button shall be located directly below the keypad at a height of 36 inches (914 mm) to 42 inches (1067 mm) above the finish floor....
- Michael Graves at TEDMED 2011
-
11B-604.8.1.1 Size
Wheelchair accessible compartments shall be 60 inches (1524 mm) wide minimum measured perpendicular to the side wall, and 56 inches (1422 mm) deep minimum for wall hung water closets and...
-
11B-604.8.1.1 Size
Wheelchair accessible compartments shall be 60 inches (1524 mm) wide minimum measured perpendicular to the side wall, and 56 inches (1422 mm) deep minimum for wall hung water closets and...
-
11B-233.3.3 Additions
required to comply with Sections 11B-233.3.1.1 _|Residential Dwelling Units with Mobility Features|_ and 11B-233.3.1.2 _|Residential Dwelling Units with Adaptable Features|_ shall be on an accessible...
-
11B-233.3.3 Additions
required to comply with Sections 11B-233.3.1.1 _|Residential Dwelling Units with Mobility Features|_ and 11B-233.3.1.2 _|Residential Dwelling Units with Adaptable Features|_ shall be on an accessible...
-
Section 35.150(b)(2) Safe harbor (Section-by-Section Analysis)
Once the compliance date is reached, such noncompliant facilities or elements must be made accessible in accordance with the 2010 Standards....
-
11B-604.8.1.1.2 Maneuvering space with side-opening door
In a wheelchair accessible compartment with a door located in the side wall or partition, either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide and 60 inches (1524 mm) deep...
-
Question 10
Is the accessible entrance into the building free of obstacles that block the clear wall and floor space needed for opening the door (between 18 and 42 inches on the latch side of the door...
-
F202.3 Alterations
Residential dwelling units not required to be accessible in compliance with a standard issued pursuant to the Architectural Barriers Act or Section 504 of the Rehabilitation Act of 1973,...
-
11B-604.8.1.1.2 Maneuvering space with side-opening door
In a wheelchair accessible compartment with a door located in the side wall or partition, either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide and 60 inches (1524 mm) deep...
-
11B-228.3.2 Minimum number
Each combination of charging level (such as: AC Level 1, AC Level 2, DC Fast Charge) and EV connector type shall be considered as a facility....
-
11B-604.2 Location
maximum from the side wall or partition, except that the water closet shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum from the side wall or partition in the ambulatory accessible...
- The A11Y Project
-
11B-604.8.1.1.2 Maneuvering space with side-opening door
In a wheelchair accessible compartment with a door located in the side wall or partition, either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide and 60 inches (1524 mm) deep...
-
§ 36.302(f)(1) General
A public accommodation shall modify its policies, practices, or procedures to ensure that individuals with disabilities can purchase tickets for accessible seating during the same hours,...
-
4.4.2 Head Room
If vertical clearance of an area adjoining an accessible route is reduced to less than 80 in (nominal dimension), a barrier to warn blind or visually-impaired persons shall be provided (...
-
4.4.2 HEAD ROOM
If vertical clearance of an area adjoining an accessible route is reduced to less than 80 in (nominal dimension), a barrier to warn blind or visually-impaired persons shall be provided (...