Tactile characters on signs shall be located 48 inches (1220 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest tactile character and 60 inches...
Search Results "Surface Slope"
-
703.4.1 Height above Finish Floor or Ground
-
M302.4.2 Clearance Around Base
the diagnostic equipment shall provide a clearance 6 inches (150 mm) high minimum measured from the floor and 36 inches (915 mm) deep minimum measured from the edge of the examination surface...
-
M301.4.2 Clearance Around Base
base of diagnostic equipment shall provide a clearance 6 inches (150 mm) high minimum measured from the floor and 36 inches (915 mm) deep minimum measured from the edge of the examination surface...
-
MEASUREMENT TECHNIQUE
MEASUREMENT TECHNIQUE The depth and width are measured along the centerlines of the seat, and the height from the floor to the highest point of the transfer surface: The depth...
-
14.2 Q. If both open and covered parking spaces are provided, how many of each type must be accessible?
., surface parking or garage, that are provided for other residents of the project....
-
4.8.1 General
One fixed showerhead shall be 48 inches (1220 mm) above the floor or ground surface, and one fixed shower head shall be 72 inches (1830 mm) minimum above the floor or ground surface....
-
68.30(3) Van Accessible Parking at Garages Constructed Prior to April 1994
If additional surface parking is provided, the required van accessible parking spaces shall be located on a surface lot in closest proximity to the accessible public entrance serving the...
-
11B-1002.4.4.3 Permitted protrusions in wheelchair spaces
protrude a distance of 6 inches (152 mm) maximum along the front of the wheelchair space, where located 9 inches (229 mm) minimum and 27 inches (686 mm) maximum above the floor or ground surface...
-
11B-801.1 Scope
For example, 806 addresses guest rooms in transient lodging facilities while 902 contains the technical specifications for dining surfaces....
-
11B-1002.4.4.3 Permitted protrusions in wheelchair spaces
protrude a distance of 6 inches (152 mm) maximum along the front of the wheelchair space, where located 9 inches (229 mm) minimum and 27 inches (686 mm) maximum above the floor or ground surface...
-
1002.4.4.3 Permitted Protrusions in Wheelchair Spaces
protrude a distance of 6 inches (150 mm) maximum along the front of the wheelchair space, where located 9 inches (230 mm) minimum and 27 inches (685 mm) maximum above the floor or ground surface...
-
801.1 Scope
For example, 806 addresses guest rooms in transient lodging facilities while 902 contains the technical specifications for dining surfaces....
-
M302.3 Supports
Transfer supports, leg supports and reclining surfaces shall comply with M302.3....
-
M301.3 Supports
Transfer supports, leg supports, and reclining surfaces shall comply with M301.3....
-
Energy Consumption During Ambulation
Subjects walked on each surface at their preferred pace, until the physiological variables (energy consumption, heart rate, velocity) had stabilized (2‒3 minutes) and the data collection...
-
R306.3.1 Separation
Detectable warning surfaces shall not be used for edge treatment....
-
11B-411.2.1.6 Identification of floors served
consoles located on floors with a building entry, including parking and transfer levels, shall be provided with signs complying with Sections 11B-703.2, 11B-703.3, and 11B-703.5 on the surface...
-
11B-1005.2.1 Height
At least 25 percent of the railings, guards, or handrails shall be 34 inches (864 mm) maximum above the ground or deck surface....
-
11B-1005.2.1 Height
At least 25 percent of the railings, guards, or handrails shall be 34 inches (864 mm) maximum above the ground or deck surface....
-
11B-411.2.1.6 Identification of floors served
consoles located on floors with a building entry, including parking and transfer levels, shall be provided with signs complying with Sections 11B-703.2, 11B-703.3, and 11B-703.5 on the surface...
-
11B-303.3 Beveled
Changes in level between ¼ inch (6.4 mm) high minimum and ½ inch (12.7 mm) high maximum shall be beveled with a slope not steeper than 1:2. [2010 ADAS] Advisory 303.3 Beveled. ...
-
Thresholds at Doorways
The 1991 Standards and the 2010 Standards require raised thresholds that exceed ¼ inch in height to be beveled on each side with a slope not steeper than 1:2....
-
Clear Deck Space
Clear Deck Space Clear deck space of 60 by 60 inches minimum, with a slope of not more than 1:48, must be provided at the base of a transfer wall....
-
4(2)
(2) In single-story dwelling units, changes in level within the dwelling unit with heights between 1/4 inch and 1/2 inch are beveled with a slope no greater than 1:2....