Independent Wheelchair Transfers in the Built Environment: How Transfer Setup Impact Performance Phase 2: Final Report REPORT PREPARED FOR: U.S ACCESS BOARD, WASHINGTON,...
Search Results "Perpendicular Parking Space"
Commonly Searched Documents
-
Independent Wheelchair Transfers in the Built Environment: How Transfer Setup Impacts Performance Phase 2: Final Report
-
Recreational Boating Facilities
Word Fillable Form (1.6MB) Word Non-Fillable Form (1.5MB) PDF Non-Fillable Form (0.8MB)
-
Lavatory and Accessory Layout by Terry Salo, Architect, CASp
Lavatory and Accessory Layout by Terry Salo, Architect, CASp NOTE: The trash receptacle is preferred to be near the door to allow people to pull the door open with a paper...
-
Application [§201]
Provisions for parking, for example, apply equally to exterior lots and to parking garages....
-
3. Maintenance of Accessible Features
spaces, ramps to building or facility entrances, door hardware, and accessible toilet facilities....
-
Lavatory & Accessory Layouts
The trash receptacle is preferred to be near the door to allow people to pull the door open with a paper towel and drop it into the receptacle before exiting.
-
F244.2.3 Elements within Camping Units with Mobility Features
This section contains the scoping requirements for elements within camping units required to provide mobility features, including outdoor constructed features (F244.2.3.1), parking spaces...
-
A4.13.11(1) Hinged doors
(1) Hinged doors: Force applied perpendicular to the door at the door opener or 30 in (760 mm) from the hinged side, whichever is farther from the hinge....
-
A4.13.11(1) Hinged doors
(1) Hinged doors: Forced applied perpendicular to the door at the door opener or 30 in (760 mm) from the hinged side, whichever is farther from the hinge....
-
Using the Tape Measure
A tape measure is used to measure the length, width, height, and depth of various elements including parking spaces and access aisles, routes, thresholds, doorways, and protruding objects...
-
ACCESSIBLE ROUTE
A continuous unobstructed path connecting all accessible elements and spaces in a building or facility....
-
Knee and Toe Space Depth
[See subsections ...]
-
Sales and Service Elements and Spaces
[See subsections ...]
-
1018.2 Aisles in assembly spaces
[DSA-AC] In addition to the requirements of this section, means of egress, which provide access to, or egress from, buildings or facilities where accessibility is required for...
-
T505.3 Location of Operable Parts
Operable parts shall be located so that they are reachable by passengers using wheelchair when parked in a clear space 30 inches (760 mm) wide minimum and 48 inches (1220 mm) long minimum...
-
1018.5 Aisles in other than assembly spaces and Groups B and M
In other than rooms or spaces used for assembly purposes and Group B and M occupancies, the minimum clear aisle capacity shall be determined by Section 1005.1 for the occupant load served...
-
1018.5 Aisles in other than assembly spaces and Groups B and M
In other than rooms or spaces used for assembly purposes and Group B and M occupancies, the minimum clear aisle capacity shall be determined by Section 1005.1 for the occupant load served...
-
2. a. Accessible route into and throughout the facility
Accessible route into and throughout the facility - The following is a 4-point guideline for ensuring equal access from the parking lot, outdoor walkways, entrances and exists of the buildings...
-
Floor and Ground Surfaces
exterior accessible routes, including walking surfaces, ramps, elevators, and lifts stairways that are part of a means of egress required clearances, including clear floor space...
-
Accessible Route
A continuous unobstructed path connecting all accessible elements and spaces of a building or facility....
-
The Impact of Transfer Setup on the Performance of Independent Transfers: Phase I Final Report
The Impact of Transfer Setup on the Performance of Independent Transfers: Final Report REPORT PREPARED FOR: U.S. ACCESS BOARD, WASHINGTON, DC Authors: Alicia Koontz, PhD,...
-
Part 1. Typical Issues for Voters Who Use Wheelchairs, Scooters or Other Mobility Aids
spaces, and other accessible elements, for example a route from a bus stop to an accessible building entrance....
-
810.2.2 Dimensions
Bus stop boarding and alighting areas shall provide a clear length of 96 inches (2440 mm) minimum, measured perpendicular to the curb or vehicle roadway edge, and a clear width of 60 inches...
-
General (R304.1) (Section-by-Section Analysis)
Curb ramps can be perpendicular or parallel, or a combination of parallel and perpendicular ramps....