The 48 inch (1220 mm) minimum width for the accessible route is necessary to ensure passage of a golf car on either the accessible route or the golf car passage....
Search Results "Clear Width"
-
11B-1006.2 Accessible routes
-
11B-235.2 Boat slips
For example, a single pier 25 feet (7620 mm) long and 5 feet (1525 mm) wide (the minimum width specified by Section 11B-1003.3) allows boats to moor on three sides....
-
(1) Transfer Surface Location for Diagnostic Equipment Used in the Supine, Prone, or Side-lying Position
The MDE Advisory Committee recommended permitting an alternative transfer surface which was rotated in its orientation such that the width paralleled the examination surface’s length and...
-
Standing Supports (M304.3 and M305.3)
o 1 side of platform for dual ramp entry of platform o 2 sides of platform for single ramp entry with 34” minimum width between standing supports o The standing supports need to be tied...
-
Sections §§ 35.108(d)(1)(vii) and 36.105(d)(1)(vii)—Comparison of Individual’s Performance of Major Life Activity Usually Will Not Require Scientific, Medical, or Statistical Analysis
Activity Usually Will Not Require Scientific, Medical, or Statistical Analysis In the NPRM, the Department proposed at §§ 35.108(d)(1)(v) and 36.105(d)(1)(v) rules of construction making clear...
-
Accessible Route to Dumpster and Enclosure
This would trigger: a level area outside the gate to accommodate the door maneuvering clearance, operable door/gate hardware, clear width at doorway, and compliant closer speed...
-
"Wheelchair" (Section-by-Section Analysis)
The Department believes that while this definition is appropriate in the limited context of federal wilderness areas, it is not specific enough to provide clear guidance in the array of...
-
"Wheelchair" (Section-by-Section Analysis)
The Department believes that while this definition is appropriate in the limited context of federal wilderness areas, it is not specific enough to provide clear guidance in the array of...
-
Expert Report of Jeromy G. Murphy, American Construction Investigations, LTD (August 6, 2018)
Building Entrance: One side of the double leaf doors at the designated accessible entrance does not provide at least 32 inches clear passage width when the door is open 90 degrees (1991...
- Adaptive Access
-
11B-805.7 Built-in cabinets and work surfaces
A 30-inch by 48-inch clear floor space, in compliance with Section 11B-305, shall be centered in front of the display screen....
-
11B-206.2.4 Spaces and elements
judges' benches, clerks' stations, bailiffs' stations, deputy clerks' stations, and court reporters' stations shall not be required to provide vertical access provided that the required clear...
-
11B-805.7 Built-in cabinets and work surfaces
A 30-inch by 48-inch clear floor space, in compliance with Section 11B-305, shall be centered in front of the display screen....
-
11B-206.2.4 Spaces and elements
judges' benches, clerks' stations, bailiffs' stations, deputy clerks' stations, and court reporters' stations shall not be required to provide vertical access provided that the required clear...
-
Shelves, Sales and Service Counters, and Check-Out Aisles
A lowered counter and clear floor space are critical components of an accessible service counter....
-
11B-1008.2.3 Water play components
Where the surface of the accessible route, clear floor or ground spaces, or turning spaces serving water play components is submerged, compliance with Sections 11B-302 _|Floor or Ground...
-
Accessible Play Components
These play components must also comply with other accessibility requirements, including specifications for clear floor space and seat heights (where provided)....
-
Shower Threshold
The Board retained the ½ inch threshold height since positioning for transfer to the seat of transfer showers can be aided where a close approach enables footrests to clear the threshold...
-
308.3.2 Obstructed High Reach
Where a clear floor or ground space allows a parallel approach to an element and the high side reach is over an obstruction, the height of the obstruction shall be 34 inches (865 mm) maximum...
-
1115B.4.5, Item 2
FIGURE 11B-8 -- CLEAR FLOOR SPACE AT BATHTUBS FIGURE 11B-9 -- GRAB BARS AT BATHTUBS ETA Editor's Note The requirements of 2010 CBC 1115B.4.5, Item 2 are identical to 1991...
-
1118B.6
If the clear floor space allows parallel approach by a person in a wheelchair, the maximum high side reach allowed shall be 54 inches (1372 mm) and the low side reach shall be no less than...
-
5.4.7 Transfer Support Gripping Surface Clearance Recommendation for M301 and M302
This clearance would allow the fingers and knuckles to clear adjacent equipment parts as they grip the support....
-
Parallel Curb Ramps (R304.3) (Section-by-Section Analysis)
The turning space must be 1.2 meters (4 feet) minimum by 1.2 meters (4 feet) minimum, and is permitted to overlap other turning spaces and clear spaces....
-
Broad Coverage
The ADA Amendments Act cleared up the confusion by stating that bodily functions are indeed major life activities....