For example, floors above or below the accessible ground floor must meet the requirements of this section except for elevator service....
Search Results "Floor Identification"
Commonly Searched Documents
-
4.1.3(5)*
-
Required Means of Egress [IBC §1007.1 (2003), §1003.2.13 (2000)]
The IBC (2003) permits one accessible means of egress from: wheelchair seating in assembly areas with sloped floors where the common path of travel meets aisle requirements for...
-
Transfer Heights
that the majority of WMDs (92% of subjects in the first phase and the 5th percentile (or approximately 94% in this study) could transfer within one inch of the mean wheelchair seat to floor...
-
BS8300:2001 Research
They include information on space required for “kneeholes,” reaching abilities of wheeled mobility users, clear floor area space requirements and maneuvering clearances....
-
A. Arena Assembly Seating:
The floor surface of the companion seat shall be at the same elevation as the floor surface of the wheelchair space....
-
11B-604.5.1 Side wall
A bath station that can be activated by a patient lying on the floor shall be provided at each room containing a patient water closet, bathtub, sitz bath, or shower stall....
-
11B-404.2.9 Door and gate opening force
is 35 inches (889 mm) minimum above the floor or ground surface....
-
Running Slope of Ramps Deployed to Roadways or Curb-Height Bus Stops
Standard transit buses had high floors (usually 35 inches above the roadway) and steps at doorways....
- Ascension Virtuoso 5460F Vertical Permanently-Installed Wheelchair Lift
- Hoyer Advance-E Power Lift
- Access-Able Designs Stationary Dressing Bench DST-101
-
ANSI/BHMA: ADA Standard Section 105.2.1
Section 105.2.1 of the ADA Standards cover references to the ANSI/BHMA standards for door durability, strength, and performance.
-
11B-805.6 Hand washing fixtures, lavatories and sinks
Section 11B-306.3.3, Exception 1 which states: "At lavatories required to be accessible by Section 11B-213.3.4, the knee clearance shall be 27 inches (686 mm) high minimum above the finish floor...
-
407.2.2.1 Visible and Audible Signals
Where in-car signals are provided, they shall be visible from the floor area adjacent to the hall call buttons. EXCEPTIONS: 1....
-
11B-217.4.1 Bank requirement
[2010 ADAS] EXCEPTION: TTYs shall not be required at banks of telephones located within 200 feet (61 m) of, and on the same floor as, a bank containing a public TTY. ...
-
1008.4.3 Play Tables
EXCEPTION: Play tables designed and constructed primarily for children 5 years and younger shall not be required to provide knee clearance where the clear floor or ground space required...
-
M302.4.1 Clearance in Base
The base of the diagnostic equipment shall provide a clearance 39 inches (990 mm) wide minimum, 6 inches (150 mm) high minimum measured from the floor, and 36 inches (915 mm) deep minimum...
-
M301.4.1 Clearance in Base
The base of diagnostic equipment shall provide a clearance 39 inches (990 mm) wide minimum, 6 inches (150 mm) high minimum measured from the floor, and 36 inches (915 mm) deep minimum measured...
-
3. Lavatory knee clearance
faucet hardware, the following features need to be provided -- a 29-inch-high clearance under the front edge of the lavatory, the top of the bowl mounted no higher than 34 inches above the floor...
-
707 Automatic Teller Machines and Fare Machines
Requirements address clear floor or ground space (707.2), operable parts (707.3), privacy (707.4), speech output (707.5), input (707.6), display screens (707.7), and braille instructions...
-
1008.4.3 Play Tables
EXCEPTION: Play tables designed and constructed primarily for children 5 years and younger shall not be required to provide knee clearance where the clear floor or ground space required...
-
604.9.6 Dispensers
The outlet of the dispenser shall be 14 inches (355 mm) minimum and 19 inches (485 mm) maximum above the finish floor....
-
608.7 Thresholds
maximum shall be permitted in transfer type shower compartments in existing facilities where provision of a 1/2 inch (13 mm) high threshold would disturb the structural reinforcement of the floor...
-
308.2.2 Obstructed High Reach
Where a high forward reach is over an obstruction, the clear floor space shall extend beneath the element for a distance not less than the required reach depth over the obstruction....