be relocated to between 48 inches measured to the baseline of the lowest tactile character and 60 inches measured to the baseline of the highest tactile character above the finish floor surface...
Search Results "Tread Surface"
Commonly Searched Documents
-
D. Signage
-
A. Accessible Entrance
Accessible Entrance Having a way to get into the emergency shelter on a surface that is firm, stable, slip resistant, without steps or steep slopes, and wide enough for a person using...
-
11B-411.2.1.6 Identification of floors served
consoles located on floors with a building entry, including parking and transfer levels, shall be provided with signage complying with Sections 11B-703.2, 11B-703.3, and 11B-703.5 on the surface...
-
4.4.1 General
In alterations, where a condition for exception in section 1.1 prohibits full compliance with a specific requirement for clear floor or ground space surface, slope, size, or location, the...
-
Conventional Strollers
The small pivoting front wheels on these strollers make them fairly easy to maneuver, but limit their use on unpaved surfaces or rough pavement....
-
11B-411.2.1.6 Identification of floors served
consoles located on floors with a building entry, including parking and transfer levels, shall be provided with signs complying with Sections 11B-703.2, 11B-703.3, and 11B-703.5 on the surface...
-
11B-602.9 Pedestrian protection
When used, wing walls or barriers shall project horizontally at least as far as the drinking fountain and to within 6 inches (152 mm) vertically from the floor or ground surface....
-
11B-1005.2.1 Height
At least 25 percent of the railings, guards, or handrails shall be 34 inches (864 mm) maximum above the ground or deck surface....
-
11B-411.2.1.6 Identification of floors served
consoles located on floors with a building entry, including parking and transfer levels, shall be provided with signs complying with Sections 11B-703.2, 11B-703.3, and 11B-703.5 on the surface...
-
11B-1005.2.1 Height
At least 25 percent of the railings, guards, or handrails shall be 34 inches (864 mm) maximum above the ground or deck surface....
- Bradley 20.6 Gallon Waste Receptacle 355
-
Executive Summary
Detectable warnings are walking surfaces that are primarily intended to provide a tactile cue to pedestrians who are visually impaired....
-
Expert Report of John Rife Torkelson, theACCESSpartnership, L.P. (August 8, 2018)
Parking: The surface slope of the designated accessible van space exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.6.3; 2010 ADA Stds 502.4)....
-
Contrast and wayfinding, short-term and long-term
Response by Marsha Mazz: I think if we decided, tomorrow, to start incorporating photo luminescent tread marking on all exit stairs, we would improve the ability of people with low vision...
- Stanley FBB 269 Heavy Weight Ball Bearing “Swing Clear” Offset Door Hinge
- Stanley FBB 266 Heavy Weight Ball Bearing “Swing Clear” Offset Door Hinge
- Stanley FBB 268 Heavy Weight Ball Bearing “Swing Clear” Offset Door Hinge
- Stanley FBB 264 Heavy Weight Ball Bearing “Swing Clear” Offset Door Hinge
-
Shared Use Paths: ADA Standard Section 2.
address access to sidewalks, streets, and other pedestrian facilities, provide requirements for pedestrian access routes, including specifications for route width, grade, cross slope, surfaces...
-
11B-609.3 Spacing
Section 11B-609.9 the space between the walls and the grab bar shall be 1½ inches (38 mm) minimum for a distance of 6 inches on either side of the inside corner between two adjacent wall surfaces...
-
11B-705.1.2.3 Islands or cut-through medians
cut-through less 2 inches (51 mm) maximum on each side, placed at the edges of the pedestrian island or cut-through median, and shall be separated by 24 inches (610 mm) minimum of walking surface...
-
404 Doors, Doorways, and Gates
series (404.2.6) clarify the height of door and gate hardware and add an exception for gates at pools, spas, and hot tubs (404.2.7) revise an exception for door and gate surface...
-
Chapter 4: Accessible Routes
Chapter 4 contains technical requirements for accessible routes (402) and the various components of such routes, including walking surfaces (403), doors, doorways and gates (404), ramps...
-
11B-406.5.12 Detectable warnings
width of the curb ramp (exclusive of flared sides) and shall extend either the full depth of the curb ramp or 24 inches (610 mm) deep minimum measured from the back of the curb on the ramp surface...