with the boarding platform or mini-high platform design such that the horizontal gap between a car at rest and the platform shall be no greater than 3 inches and the height of the car floor...
Search Results "Floor Button"
Commonly Searched Documents
-
§ 38.113(d)(1) Requirements
-
1130A.1 General
The accessible route shall pass through the primary entry door, and shall connect with all additional exterior doors, required clear floor spaces at kitchen appliances and bathroom fixtures...
-
11B-604.7.1 Dispensers
The outlet of the dispenser shall be below the grab bar, 19 inches (483 mm) minimum above the finish floor and shall not be located behind grab bars....
-
1133A.3 Removable base cabinets
The finish floor beneath kitchen sinks and work surfaces shall be extended to the wall....
-
11B-233.3.1.2.4 Multi-story residential dwelling units in buildings with one or more elevators
multi-story residential dwelling units shall comply with the following: The primary entry of the multi-story residential dwelling unit shall be on an accessible route on the floor...
-
1133A.3 Removable base cabinets
The finish floor beneath kitchen sinks and work surfaces shall be extended to the wall....
-
11B-604.7.1 Dispensers
The outlet of the dispenser shall be below the grab bar, 19 inches (483 mm) minimum above the finish floor and shall not be located behind grab bars....
-
11B-809.9.3 Removable base cabinets
sinks and work surfaces provided that all of the following conditions are met: a) base cabinets can be removed without the use of specialized tools or knowledge; b) the finish floor...
-
1130A.1 General
The accessible route shall pass through the primary entry door, and shall connect with all additional exterior doors, required clear floor spaces at kitchen appliances and bathroom fixtures...
-
General Tips
Potted plants, benches, ashtrays, trash cans, and other items blocking access to ramps, railings, and elevator call buttons....
- Guldmann Basic High Sling - Kids
-
Running Slope of Ramps Deployed to Roadways or Curb-Height Bus Stops
Standard transit buses had high floors (usually 35 inches above the roadway) and steps at doorways....
-
11B-404.2.9 Door and gate opening force
is 35 inches (889 mm) minimum above the floor or ground surface....
-
Transfer Heights
that the majority of WMDs (92% of subjects in the first phase and the 5th percentile (or approximately 94% in this study) could transfer within one inch of the mean wheelchair seat to floor...
-
BS8300:2001 Research
They include information on space required for “kneeholes,” reaching abilities of wheeled mobility users, clear floor area space requirements and maneuvering clearances....
-
A. Arena Assembly Seating:
The floor surface of the companion seat shall be at the same elevation as the floor surface of the wheelchair space....
-
11B-604.5.1 Side wall
A bath station that can be activated by a patient lying on the floor shall be provided at each room containing a patient water closet, bathtub, sitz bath, or shower stall....
-
Section 307 Protruding Objects
This dryer protrudes more than 4" from the wall and is greater than 27" above the finish floor. Isn't this a violation of Section 307 Protruding Objects?...
-
Shower Compartments
inch maximum curb in transfer-type showers in alterations to existing facilities, where recessing the compartment to achieve a ½-inch curb will disturb the structural reinforcement of the floor...
-
M301.4 Lift Compatibility
M01.4.1 Clearance in Base Proposed requirement: The base of the equipment shall provide a clearance 44 inches (1120 mm) wide minimum, 6 inches (150 mm) high minimum measured from the floor...
-
Display Screens
suggested that we change the requirement for display screens such that they must not only be visible, but also readable, from a point located 40 inches (1015 mm) above the center of the clear floor...
-
4.1.3(5)*
For example, floors above or below the accessible ground floor must meet the requirements of this section except for elevator service....
-
Required Means of Egress [IBC §1007.1 (2003), §1003.2.13 (2000)]
The IBC (2003) permits one accessible means of egress from: wheelchair seating in assembly areas with sloped floors where the common path of travel meets aisle requirements for...
-
11B-608.3 Grab bars
Where multiple grab bars are used, required horizontal grab bars shall be installed at the same height above the finish floor....