A transfer space complying with Sections 11B-305.2 and 11B-305.3 shall be provided adjacent to the transfer platform....
Search Results "Transfer Shower"
-
11B-1008.3.1.3 Transfer space
-
11B-1008.3.1.3 Transfer space
A transfer space complying with Sections 11B-305.2 and 11B-305.3 shall be provided adjacent to the transfer platform....
-
11B-1009.1 General
Where provided, pool lifts, sloped entries, transfer walls, transfer systems, and pool stairs shall comply with Section 11B-1009....
-
11B-1009.1 General
Where provided, pool lifts, sloped entries, transfer walls, transfer systems, and pool stairs shall comply with Section 11B-1009....
-
11B-1008.3.2.3 Transfer supports
At least one means of support for transferring shall be provided. [2010 ADAS] Advisory 1008.3.2.3 Transfer Supports. ...
-
11B-1008.3.2.3 Transfer supports
At least one means of support for transferring shall be provided. [2010 ADAS] Advisory 1008.3.2.3 Transfer Supports....
-
11B-1008.3.2.3 Transfer supports
At least one means of support for transferring shall be provided. Advisory 11B-1008.3.2.3 Transfer supports....
-
Wheelchair Transfer
Wheelchair Transfer The manner of approach and transfer to water closets varies among people with disabilities....
- Delta Palm Hand Shower Head - Model 53001-DS
-
1008.3.1.4 Transfer Supports
At least one means of support for transferring shall be provided....
-
1008.3.1.4 Transfer Supports
At least one means of support for transferring shall be provided....
-
11B-1009.5.4 Transfer steps
Transfer step height shall be 8 inches (203 mm) maximum. The surface of the bottom tread shall extend to a water depth of 18 inches (457 mm) minimum below the stationary water level....
-
11B-1009.5.4 Transfer steps
Transfer step height shall be 8 inches (203 mm) maximum....
-
Curbs [4.21.7]
Curbs [4.21.7] Curbs are limited to ½ inch (measured from the room floor and the shower floor) so as not to interfere with entry to the shower....
-
608.6 Shower Spray Unit and Water
608.6 Shower Spray Unit and Water....
-
608.6 Shower Spray Unit and Water
A shower spray unit with a hose 59 inches (1500 mm) long minimum that can be used both as a fixed-position shower head and as a hand-held shower shall be provided....
-
608.6 Shower Spray Unit and Water
A shower spray unit with a hose 59 inches (1500 mm) long minimum that can be used both as a fixed-position shower head and as a hand-held shower shall be provided....
-
608.6 Shower Spray Unit and Water
A shower spray unit with a hose 59 inches (1500 mm) long minimum that can be used both as a fixed-position shower head and as a hand-held shower shall be provided....
-
1008.3.1 Transfer Platforms
1008.3.1 Transfer Platforms. Transfer platforms shall be provided where transfer is intended from wheelchairs or other mobility aids. Transfer platforms shall comply with 1008.3.1....
-
1008.3.1 Transfer Platforms
Transfer platforms shall be provided where transfer is intended from wheelchairs or other mobility aids. Transfer platforms shall comply with 1008.3.1....
-
Location of Controls
In transfer compartments, controls, faucets, and shower spray units were to be located no more than 15 inches on either side of the seat centerline, according to the proposed rule (608.5.1...
-
11B-1008.3.1.4 Transfer supports
At least one means of support for transferring shall be provided. FIGURE 11B-1008.3.1 TRANSFER PLATFORMS...
-
608.2 Size and Clearances for Shower Compartments
608.2 Size and Clearances for Shower Compartments. Shower compartments shall have sizes and clearances complying with 608.2....
-
1008.3.1 Transfer Platforms
Transfer platforms shall be provided where transfer is intended from wheelchairs or other mobility aids. Transfer platforms shall comply with 1008.3.1....