Clear openings of doorways with swinging doors shall be measured between the face of the door and the stop, with the door open 90° degrees.xiv...
Search Results "Swing"
-
2. b. i. Clear door openings
-
Automatic Door Break Out Openings
Automatic bi-parting doors or pairs of swinging doors that provide a 32-inch minimum clear break out opening in emergency mode when both leaves are opened manually meet the technical requirement...
-
1132A.3 Width and height of interior doors and secondary exterior doors
Swinging doors shall provide a net clear opening width of not less than 32 inches (813 mm), measured with the door or doors positioned at an angle of 90 degrees from the closed position....
-
11B-407.3.2 Operation
Exception: Existing manually operated hoistway swing doors shall be permitted provided that they comply with Sections 11B-404.2.3 and 11B-404.2.9....
-
11B-407.3.2 Operation
Exception: Existing manually operated hoistway swing doors shall be permitted provided that they comply with Sections 11B-404.2.3 and 11B-404.2.9....
-
11B-407.3.2 Operation
Exception: Existing manually operated hoistway swing doors shall be permitted provided that they comply with Sections 11B-404.2.3 and 11B-404.2.9....
-
Single-User Toilet Rooms: Side Transfer Space
Doors can swing into the turning space but not the clear floor space required at fixtures....
-
1010.1.5 Floor elevation
dwelling units in Groups R-2 and R-3 where the following apply: 1.1 A door is permitted to open at the top step of an interior flight of stairs, provided that the door does not swing...
-
Question 10
of obstacles that block the clear wall and floor space needed for opening the door (between 18 and 42 inches on the latch side of the door, depending on direction of approach and door swing...
-
H6
If the entry has a vestibule, is there a 30-inch by 48-inch clear floor space inside the vestibule where a wheelchair or scooter user can be outside the door swing?...
-
Location: ADA Standard Section 703.4.2
characters shall be located so that a clear floor space of 18 inches (455 mm) minimum by 18 inches (455 mm) minimum, centered on the tactile characters, is provided beyond the arc of any door swing...
-
Question 19
of obstacles that block the clear wall and floor space needed for opening the door (between 18 and 42 inches on the latch side of the door, depending on direction of approach and door swing...
-
D6
If an entry has a vestibule, is there a 30-inch by 48-inch clear floor space inside the vestibule where a wheelchair or scooter user can be outside the swing of a hinged door?...
-
11B-604.8.2.2 Doors
Toilet compartment doors shall not swing into the minimum required compartment area. [2010 ADAS] 604.8.2.2 Doors....
-
11B-604.8.2.2 Doors
Toilet compartment doors shall not swing into the minimum required compartment area. [2010 ADA Standards] 604.8.2.2 Doors....
-
612.2 Bench
Doors shall not swing into the clear floor space required by 903.2....
-
612.2 Bench
Doors shall not swing into the clear floor space required by 903.2....
-
612.2 Bench
Doors shall not swing into the clear floor space required by 903.2....
-
K. Ambulatory Stall
are more than 5 stalls in any restroom, is there one stall in addition to the large accessible stall, that is 36" wide, has 2 parallel grab bars at 33"-36" off the floor and has an out-swinging...
-
Water Closet Clearances
The primary effect of the Department’s proposed final rules governing water closet clearances in single-user toilet rooms with in-swinging and out-swinging doors is to allow sufficient room...
-
Water Closet Clearances
The primary effect of the Department's proposed final rules governing water closet clearances in single-user toilet rooms with in-swinging and out-swinging doors is to allow sufficient room...
-
Clear Width: ADA Standard Section 404.2.3
Section 404.2.3 covers the current ADA Standards for clear width at manual doors, doorways and manual gates that are part of an accessible route.
-
11B-404.2.3 Clear width
Clear openings of doorways with swinging doors shall be measured between the face of the door and the stop, with the door open 90 degrees....
-
11B-404.2.3 Clear width
Clear openings of doorways with swinging doors shall be measured between the face of the door and the stop, with the door open 90 degrees....