Product Features 1 1/4" bar diameter. Exposed Flange. Custom sizes available upon request. Peened saftey grip. Product Specs Tubing: Fabricated of #18 ga stainless...
Search Results "Stair Handrail"
Commonly Searched Documents
- AJW Architectural Products UG120-Railing UG120X-Y108 108" Exposed Flange, 1.25" Diameter, Peened Grip - Configuration Y
-
504.5 Nosings
Figure 504.5 Stair Nosings...
-
11B-1009.6.1 Pool stairs
Pool stairs shall comply with Section 11B-504....
-
504.5 Nosings
Figure 504.5 Stair Nosings...
-
11B-1009.6.1 Pool stairs
Pool stairs shall comply with Section 11B-504 _|Stairways|_....
-
11B-1009.6.1 Pool stairs
Pool stairs shall comply with Section 11B-504 _|Stairways|_....
-
R409.10.1 Top and Bottom Extension at Ramps
Ramp handrails shall extend horizontally above the landing for 305 mm (1.0 ft) minimum beyond the top and bottom of ramp runs....
-
4.8.5(7)
(7) Handrails shall not rotate within their fittings....
-
T303.3.2 Handrail and Stanchion Circular Cross Section
Handrails and stanchions with a circular cross section shall have an outside diameter of 1¼ inches (32 mm) minimum and 2 inches (50 mm) maximum....
-
11B-1008.2.5.3.1 Handrail gripping surfaces
Handrail gripping surfaces with a circular cross section shall have an outside diameter of 0.95 inch (24 mm) minimum and 1.55 inches (39 mm) maximum....
-
4.8.5(3)
(3) The clear space between the handrail and the wall shall be 1 - 1/2 in (38 mm)....
-
4.8.5(5)
(5) Top of handrail gripping surfaces shall be mounted between 34 in and 38 in (865 mm and 965 mm) above ramp surfaces....
-
Is there a maximum distance between ramp handrails?
No, only a minimum (36”) is required between handrails. The Standards do not require center or intermediate handrails on wide ramps....
-
4.8.5(2)
(2) If handrails are not continuous, they shall extend at least 12 in (305 mm) beyond the top and bottom of the ramp segment and shall be parallel with the floor or ground surface (see Fig...
-
1009.3.3 Handrails
1009.3.3 Handrails. At least two handrails complying with 505 shall be provided on the sloped entry....
-
1008.2.5.3.2 Handrail Height
1008.2.5.3.2 Handrail Height. The top of handrail gripping surfaces shall be 20 inches (510 mm) minimum and 28 inches (710 mm) maximum above the ramp surface....
-
R408.2 Treads and Risers
All steps on a flight of stairs shall have uniform riser heights and uniform tread depths. Risers shall be 100 mm (4 in) high minimum and 180 mm (7 in) high maximum....
-
4.8.5(6)
(6) Ends of handrails shall be either rounded or returned smoothly to floor, wall, or post....
-
§ 38.97(a)
(a) Where provided, handrails or stanchions within the passenger compartment shall be placed to permit sufficient turning and maneuvering space for wheelchairs and other mobility aids to...
-
1008.2.5.3.2 Handrail Height
The top of handrail gripping surfaces shall be 20 inches (510 mm) minimum and 28 inches (710 mm) maximum above the ramp surface....
-
1008.2.5.3.2 Handrail Height
The top of handrail gripping surfaces shall be 20 inches (510 mm) minimum and 28 inches (710 mm) maximum above the ramp surface....
-
Clearances between a handrail and wall surface: 2012 NFPA 101 vs. 2010 ADA
Question/Issue: According to the new 2012 NFPA 101 Life Safety Code, Chapter 7, Section 7.2.2.4.4.5 & Exhibit 7.97, the finger clearance at an existing stair handrail should be...
-
11B-504.5 Nosings
Additionally, because it is possible to catch the top of one’s shoe on the underside of stair nosings, access compliance regulations require the underside of nosings to be free of abrupt...
-
11B-504.5 Nosings