Buttons shall be arranged in columns to the right of the keypad with a minimum horizontal spacing of 1.5 times the horizontal spacing between the numeric keys and with the same vertical...
Search Results "Raised Button"
Commonly Searched Documents
-
11B-411.2.1.4.1.1 Arrangement
-
R209 Accessible Pedestrian Signals and Pedestrian Pushbuttons (Section-by-Section Analysis)
R209 Accessible Pedestrian Signals and Pedestrian Pushbuttons (Section-by-Section Analysis) An accessible pedestrian signal and pedestrian pushbutton is an integrated device that...
-
R307 Accessible Pedestrian Signals and Pedestrian Pushbuttons (See R209) (Section-by-Section Analysis)
R307 Accessible Pedestrian Signals and Pedestrian Pushbuttons (See R209) (Section-by-Section Analysis) In the 2005 draft of the proposed guidelines, the technical requirements for...
-
R209.1 General
R209.1 General. Where pedestrian signals are provided at pedestrian street crossings, they shall include accessible pedestrian signals and pedestrian pushbuttons complying with...
-
R209 Accessible Pedestrian Signals and Pedestrian Pushbuttons
R209 Accessible Pedestrian Signals and Pedestrian Pushbuttons
-
R307 Accessible Pedestrian Signals and Pedestrian Pushbuttons (See R209)
R307 Accessible Pedestrian Signals and Pedestrian Pushbuttons (See R209)
-
16) Elevator hoistway floor designations and car controls
16) Elevator hoistway floor designations and car controls ADAAG: Must have raised and brailled characters (§§4.10.5; 4.10.12)....
-
407.2.1.3 Clear Floor or Ground Space
The clear floor or ground space required at elevator call buttons must remain free of obstructions including ashtrays, plants, and other decorative elements that prevent wheelchair users...
-
407.2.1.3 Clear Floor or Ground Space
The clear floor or ground space required at elevator call buttons must remain free of obstructions including ashtrays, plants, and other decorative elements that prevent wheelchair users...
-
11B-407.2.1.3 Clear floor or ground space
The clear floor or ground space required at elevator call buttons must remain free of obstructions including ashtrays, plants, and other decorative elements that prevent wheelchair users...
-
11B-407.2.1.3 Clear floor or ground space
The clear floor or ground space required at elevator call buttons must remain free of obstructions including ashtrays, plants, and other decorative elements that prevent wheelchair users...
-
11B-407.2.1.3 Clear floor or ground space
The clear floor or ground space required at elevator call buttons must remain free of obstructions including ashtrays, plants, and other decorative elements that prevent wheelchair users...
-
407.2.1.3 Clear Floor or Ground Space
The clear floor or ground space required at elevator call buttons must remain free of obstructions including ashtrays, plants, and other decorative elements that prevent wheelchair users...
-
407.2.1.5 Signals
Call buttons shall have visible signals to indicate when each call is registered and when each call is answered. EXCEPTIONS: 1....
-
407.2.1.5 Signals
Call buttons shall have visible signals to indicate when each call is registered and when each call is answered. EXCEPTIONS: 1....
-
407.2.1.5 Signals
Call buttons shall have visible signals to indicate when each call is registered and when each call is answered. EXCEPTIONS: 1....
-
4.10.12(3)
All floor buttons shall be no higher than 54 in (1370 mm) above the finish floor for side approach and 48 in (1220 mm) for front approach....
-
4.10.12(3)
All floor buttons shall be no higher than 48 in (1220 mm), unless there is a substantial increase in cost, in which case the maximum mounting height may be increased to 54 in (1370 mm),...
-
703.2.6 Stroke Thickness
703.2.6 Stroke Thickness. Stroke thickness of the uppercase letter "I" shall be 15 percent maximum of the height of the character.
-
11B-703.2.6 Stroke thickness
Stroke thickness of the uppercase letter “I” shall be 15 percent maximum of the height of the character.
-
703.2.6 Stroke Thickness
Stroke thickness of the uppercase letter "I" shall be 15 percent maximum of the height of the character.
-
703.2.6 Stroke Thickness
Stroke thickness of the uppercase letter "I" shall be 15 percent maximum of the height of the character. [ECTCR UFAS 4.30.4]
-
11B-703.2.6 Stroke thickness
11B-703.2.6 Stroke thickness. Stroke thickness of the uppercase letter “I” shall be 15 percent maximum of the height of the character.
-
11B-703.2.6 Stroke thickness
Stroke thickness of the uppercase letter “I” shall be 15 percent maximum of the height of the character.