A commenter advised that no revolving doors or turnstiles should be permitted on an accessible route. Response....
Search Results "Exit Door"
-
Revolving Doors or Turnstiles
-
202.3.3 Barriers at Common or Emergency Entrances and Exists
Barriers at common or emergency entrances and exits of business establishments conducting business with the general public that are existing, under construction, or under contract for construction...
-
4.13.9* DOOR HARDWARE
When sliding doors are fully open, operating hardware shall be exposed and usable from both sides....
-
Door and Gate Hardware
Section 404.2.7 also covers the operating characteristics and height of door and gate hardware....
-
11B-604.8.2.2 Doors
Toilet compartment doors, including door hardware, shall comply with Section 11B-404, except that if the approach is to the latch side of the compartment door, clearance between the door...
-
11B-604.8.1.2 Doors
11B-604.8.1.2 Doors....
-
11B-604.8.1.2 Doors
Toilet compartment doors, including door hardware, shall comply with Section 11B-404 except that if the approach is from the push side of the compartment door, clearance between the door...
-
11B-604.8.1.2 Doors
Toilet compartment doors, including door hardware, shall comply with Section 11B-404 except that if the approach is from the push side of the compartment door, clearance between the door...
-
11B-411.3.5 Width
The width of elevator doors shall comply with Table 11B-407.4.1....
-
11B-411.3.5 Width
The width of elevator doors shall comply with Table 11B-407.4.1....
-
11B-404.2.8.1 Door closers and gate closers
Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum...
-
11B-404.2.8.1 Door closers and gate closers
Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum...
-
1009.2 Continuity and components
Interior exit stairways complying with Sections 1009.3 and 1023, and Chapter 11A, Section 1123A, or Chapter 11B, Sections 11B-210 and 11B-504, as applicable....
-
1009.2 Continuity and components
Interior exit stairways complying with Sections 1009.3 and 1023, and Chapter 11A, Section 1123A, or Chapter 11B, Sections 11B-210 and 11B-504, as applicable....
-
Doors in a Series
A few commenters expressed concern that the Guidelines did not provide design for an entrance that consists of a series of more than one door....
-
11B-404.2.8.1 Door closers and gate closers
Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum...
-
1991 / 1994 ADA Standards - Plan Review Tool - Doors
1991 / 1994 ADA Standards - Plan Review Tool - Doors Click here to view/download the pdf, Page 1 of 2 (256 KB) Click here to view/download the pdf, Page 2 of 2 (272 KB) * * * *...
-
11B-409.3 Elevator doors
Hoistway doors, car doors, and car gates shall comply with Sections 11B-409.3 and 11B-404....
-
11B-409.3 Elevator doors
Hoistway doors, car doors, and car gates shall comply with Sections 11B-409.3 and 11B-404....
-
11B-409.3 Elevator doors
Hoistway doors, car doors, and car gates shall comply with Sections 11B-409.3 and 11B-404....
-
4.13.9* Door Hardware
Handles, pulls, latches, locks, and other operating devices on accessible doors shall have a shape that is easy to grasp with one hand and does not require tight grasping, tight pinching...
-
Doors at Entrances to Businesses
Doors at Entrances to Businesses Most entrances to stores and businesses use 36 inch wide doors that are wide enough to be accessible....
-
1010.1.6 Thresholds
or landing for other doors....
-
1010.1.6 Thresholds
or landing for other doors....