All doors to accessible toilet rooms shall comply with 4.13. Doors shall not swing into the clear floor space required for any fixture....
Search Results "Entry Door (FHA)"
Commonly Searched Documents
-
4.22.2 Doors
-
4.22.2 DOORS
All doors to accessible toilet rooms shall comply with 4.13. Doors shall not swing into the clear floor space required for any fixture....
-
§100.205(c)(3)(iii)
(iii) Reinforcements in bathroom walls to allow later installation of grab bars around the toilet, tub, shower, stall and shower seat, where such facilities are provided; and
-
404 Doors, Doorways, and Gates
Changes made to the requirements for manually operated doors: clarify coverage of gates and the application of this section to manual doors and doorways intended for user passage...
- SafePath: Overview of Ramps and Reducers for ADA Compliance by SafePath Products
-
4.13.7 Two Doors in Series
The minimum space between two hinged or pivoted doors in series shall be 48 in (1220 mm) plus the width of any door swinging into the space....
-
4.13.7 TWO DOORS IN SERIES
The minimum space between two hinged or pivoted doors in series shall be 48 in (1220 mm) plus the width of any door swinging into the space....
-
R218 Doors, Doorways, and Gates
R218 Doors, Doorways, and Gates. Where provided at pedestrian facilities, doors, doorways, and gates shall comply with section 404 of Appendix D to 36 CFR part 1191....
-
11B-604.8.1.1.1 Maneuvering space with in-swinging door
In a wheelchair accessible compartment with an in-swinging door, a minimum 60 inches (1524 mm) wide by 36 inches (914 mm) deep maneuvering space shall be provided in front of the clearance...
-
11B-809.8 Doors
Primary entry doors, required exit doors, secondary exterior doors and interior doors intended for user passage shall comply with this section and Section 11B-404.2....
-
Swimming Pools
The primary means of entry must be either a sloped entry into the water or a pool lift that is capable of being independently operated by a person with a disability. ...
-
1009.3.2 Submerged Depth
Sloped entries shall extend to a depth of 24 inches (610 mm) minimum and 30 inches (760 mm) maximum below the stationary water level....
-
SECTION 1010 DOORS, GATES AND TURNSTILES
[DSA-AC] In addition to the requirements of this section, means of egress, which provide access to, or egress from, buildings or facilities where accessibility is required for...
-
11B-1009.3.2 Submerged depth
Sloped entries shall extend to a depth of 24 inches (610 mm) minimum and 30 inches (762 mm) maximum below the stationary water level....
-
11B-1009.3.2 Submerged depth
Sloped entries shall extend to a depth of 24 inches (610 mm) minimum and 30 inches (762 mm) maximum below the stationary water level....
-
Common Problems with Entrances and Doors
Common Problems with Entrances and Doors Ø Each leaf of a set of double doors is often too narrow to be used independently by someone who uses a wheelchair....
-
Door Closing Speed Tool
Door Closing Speed Tool This handy tool was developed by Evan Terry Associates to assist its surveyors in measuring door closing speed....
-
6d.
Does the lift allow a wheelchair user unassisted entry, operation, and exit? Yes _____ No _____...
-
3.2 Q. If a condominium is pre-sold as a shell and the interior is designed and constructed by the buyer, are the Guidelines applicable?
A. Yes. The Fair Housing Act applies to design and construction of covered multifamily dwellings, regardless of whether the person doing the design and construction is an architect,...
-
Section 2. Dwelling unit
"Dwelling unit" means a single unit of residence for a household of one or more persons. Examples of dwelling units covered by these guidelines include: condominiums; an apartment...
-
§100.201 Dwelling unit
Dwelling unit means a single unit of residence for a family or one or more persons. Examples of dwelling units include: a single family home; an apartment unit within an apartment...
-
AUTOMATIC DOOR
A door equipped with a power-operated mechanism and controls that open and close the door automatically upon receipt of a momentary actuating signal....
-
1132A.2 Interior doors and secondary exterior doors
1132A.2 Interior doors and secondary exterior doors....
-
Changes in Level within a Dwelling Unit
The Department, however, does require that design features, such as a split-level entry, which is critical to providing an accessible route into and through the unit, must provide a ramp...