(2) Clear aisle width for accessible check-out aisles shall comply with 4.2.1 and maximum adjoining counter height shall not exceed 38 in (965 mm) above the finish floor....
Search Results "Counter Depth"
-
7.3(2)
-
11B-804.3.2 Height
Exception: A counter that is adjustable to provide a kitchen work surface at variable heights, 29 inches (737 mm) minimum and 36 inches (914 mm) maximum, shall be permitted....
-
804.3.2 Height
EXCEPTION: A counter that is adjustable to provide a kitchen work surface at variable heights, 29 inches (735 mm) minimum and 36 inches (915 mm) maximum shall be permitted....
-
11B-804.3.2 Height
Exception: A counter that is adjustable to provide a kitchen work surface at variable heights, 29 inches (737 mm) minimum and 36 inches (914 mm) maximum, shall be permitted....
-
11B-804.3.2 Height
Exception: A counter that is adjustable to provide a kitchen work surface at variable heights, 29 inches (737 mm) minimum and 36 inches (914 mm) maximum, shall be permitted....
-
804.3.2 Height
EXCEPTION: A counter that is adjustable to provide a kitchen work surface at variable heights, 29 inches (735 mm) minimum and 36 inches (915 mm) maximum, shall be permitted....
-
11B-902.4.2 Height
The tops of tables and counters shall be 26 inches (660 mm) minimum and 30 inches (762 mm) maximum above the finish floor or ground....
-
11B-902.4.2 Height
The tops of tables and counters shall be 26 inches (660 mm) minimum and 30 inches (762 mm) maximum above the finish floor or ground....
-
804.3.2 Height
EXCEPTION: A counter that is adjustable to provide a kitchen work surface at variable heights, 29 inches (735 mm) minimum and 36 inches (915 mm) maximum, shall be permitted....
-
Built-in Elements
11B-226, 11B-902.2 Benches 11B-903.2 Check out aisles 11B-904.3.2 Sales/service counters...
-
Built-in Elements
11B-226, 11B-902.2 Benches 11B-903.2 Check out aisles 11B-904.3.2 Sales/service counters...
-
Maximum side reach ranges. (Section-by-Section Analysis)
Reach ranges apply to a variety of building elements, including light switches, key pads, electrical outlets, fire alarm pulls, card readers, thermostats, elevator controls, pay...
-
G. Compartment Size
G. If the accessible toilet is in a stall, does the stall measure at least 60" wide and 56" deep if it is wall mounted or 59" deep if it is floor mounted to allow persons who use...
-
Side Approach and Reach
[See subsections ...]
-
Obstructed High Reach
The maximum high reach is reduced to 46” when the reach over an obstruction is deeper than 10” (to a maximum of 24”). Obstructions at side reaches are limited to a height of...
-
11B-220.2 Point-of-sale devices
Where point-of-sale devices are provided at check stands and sales and service counters required to comply with Sections 11B-227.2 and 11B-227.3, they shall comply with Sections 11B-707.2...
-
11B-220.2 Point-of-sale devices
Where point-of-sale devices are provided at check stands and sales and service counters, they shall comply with Section 11B-707.9.1, and shall also comply with Sections 11B-707.2 _|Clear...
-
A2.2 Equivalent Facilitation
equivalent facilitation are found in the following sections: 4.1.6(3)(c) Elevators in Alterations 4.31.9 Text Telephones 7.2 Sales and Service Counters...
-
11B-220.2 Point-of-sale devices
Where point-of-sale devices are provided at check stands and sales and service counters required to comply with Sections 11B-227.2 and 11B-227.3, they shall comply with Sections 11B-707.2...
-
Q1.) When a ramp has a maximum slope of 1:12 or 8.33%, is that considered a range of from 0% to 8.33% which would allow no slope greater than 8.33% or is that a simple maximum which would allow a tolerance above 8.33%? Similarly, is a cabinet countertop that can be no higher than 34” AFF a range of from 0” to 34” AFF with no additional height allowed, or is a tolerance allowed for variations in the floor surface or cabinet construction?
A1.) The consistent technical assistance on this question has been that both are subject to tolerances.