Side Approach Side reach depth is important to consider in the design and location of sinks....
Search Results "Counter Depth"
Commonly Searched Documents
-
Side Approach
-
Check-Out Areas [8.3]
Check-Out Areas [8.3] Check-out counters at accessible lanes are held to a maximum surface height of 36 inches....
-
Side Approach
In June 1993, additional specifications were provided for the maximum height based on the reach depth....
-
308 Reach Ranges
Accessible reach ranges are specified according to the approach (forward or side) and the depth of reach over any obstruction....
-
Wall Depth and Length: ADA Standard Section 1009.4.3
The depth of the transfer wall shall be 12 inches (305 mm) minimum and 16 inches (405 mm) maximum....
-
Question 14
Are the accessible checkout aisles and sales counters staffed during all business hours?...
-
11B-308.3.1 Unobstructed
Exceptions: An obstruction shall be permitted between the clear floor or ground space and the element where the depth of the obstruction is 10 inches (254 mm) maximum....
-
Depth: ADA Standard Section 703.2.1
Raised characters shall be 1/32 inch (0.8 mm) minimum above their background.
-
Depth: ADA Standard Section 802.1.3
Where a wheelchair space can be entered from the front or rear, the wheelchair space shall be 48 inches (1220 mm) deep minimum. Where a wheelchair space can be entered only from the...
-
308.3.1 Unobstructed
An obstruction shall be permitted between the clear floor or ground space and the element where the depth of the obstruction is 10 inches (255 mm) maximum. 2....
-
308.3.1 Unobstructed
An obstruction shall be permitted between the clear floor or ground space and the element where the depth of the obstruction is 10 inches (255 mm) maximum. 2....
-
11B-308.3.1 Unobstructed
An obstruction shall be permitted between the clear floor or ground space and the element where the depth of the obstruction is 10 inches (254 mm) maximum. 2. ...
-
308.3.1 Unobstructed
An obstruction shall be permitted between the clear floor or ground space and the element where the depth of the obstruction is 10 inches (255 mm) maximum. 2....
-
308.3.1 Unobstructed
An obstruction shall be permitted between the clear floor or ground space and the element where the depth of the obstruction is 10 inches (255 mm) maximum. 2....
-
11B-308.3.1 Unobstructed
An obstruction shall be permitted between the clear floor or ground space and the element where the depth of the obstruction is 10 inches (254 mm) maximum. 2. ...
-
4 [§ 4.7.2]
4 [§ 4.7.2] The gutter is the part of the street that borders the curb. To measure the gutter slope, place the level in the same position as the arrow in the illustration, with...
-
1133A.4 Countertops
1133A.4 Countertops. Kitchen countertops shall comply with this section and shall be provided with the following:
-
Transition to Street [§406.2]
Transition to Street [§406.2]
-
1133A.4 Countertops
Kitchen countertops shall comply with this section and shall be provided with the following:
-
1133A.4 Countertops
Kitchen countertops shall comply with this section and shall be provided with the following: A minimum linear length of 30 inches (762 mm) of countertop shall be provided for...
-
4.25.3 Height
Where the distance from the wheelchair to the clothes rod or shelf exceeds 10 in (255 mm) (as in closets without accessible doors) the height and depth to the rod or shelf shall comply with...
-
Slope [4.7.2]
Severe counter slopes can do the same thing and cause footrests to scrape....
-
11B-604.8.1.1 Size
Wheelchair accessible compartments shall be 60 inches (1524 mm) wide minimum measured perpendicular to the side wall, and 56 inches (1422 mm) deep minimum for wall hung water closets...
-
F231.4.2 Partitions
Where solid partitions or security glazing separate visitors from detainees, at least one of each type of cubicle or counter partition shall comply with 904.6....