Manufacturers of telecommunications equipment shall comply with the requirements in the 255 Guidelines applicable to such equipment when newly released, upgraded, or substantially changed...
Search Results "CPE: Customer Premises Equipment"
-
C201.1 Scope
-
5.3.1 Permitted Obstructions to Transfer Sides for Equipment Used by Patients in a Supine, Prone, Side-Lying or Seated Position
5.3.1 Permitted Obstructions to Transfer Sides for Equipment Used by Patients in a Supine, Prone, Side-Lying or Seated Position....
-
2. Equipment Clearances for Breast Platforms
Additionally, this commenter raised concerns that mammography equipment must have a stabilizing flange or foot at its base to prevent the equipment from tipping when the gantry is extended...
-
M301.1 General
Where diagnostic equipment is used by patients in a supine, prone, or side-lying position, it shall comply with M301....
-
M101.2 Application
Sections M301 through M304 shall be applied to diagnostic equipment, based on the patient positions that the equipment supports, during patient transfer and diagnostic use....
- Senographe Essential eContrast
-
5.2.1.1 Transfer Surface Width
The transfer surface should be 28 inches wide minimum for equipment used by patients in a supine, side-lying, or prone position....
-
M301.4 Lift Compatibility
An overhead lift (and possibly a gurney-based transfer) may be used in lieu of the provisions for clearances in or around the base of equipment to accommodate the legs of portable floor...
-
5.8 Wheelchair Spaces Recommendations for M303 Diagnostic Equipment Used by Patients Seated in a Wheelchair
5.8 Wheelchair Spaces Recommendations for M303 Diagnostic Equipment Used by Patients Seated in a Wheelchair...
-
M301.2.3 Size (Section-by-Section Analysis)
The MDE NPRM proposed a transfer surface size for diagnostic equipment used in the supine, prone, or side-lying position of 30 inches wide and 15 inches deep minimum....
-
M301.2.2 Size
The size requirements in this section apply only to the portion of the diagnostic equipment used for transfer....
-
Telecommunications Act
Section 255 and Section 251(a)(2) of the Communications Act of 1934, as amended by the Telecommunications Act of 1996, require manufacturers of telecommunications equipment and providers...
-
M301.1 General
Diagnostic equipment that supports patients in a supine, prone, or side-lying position shall comply with M301. ...
-
M304 Diagnostic Equipment Used by Patients in Standing Position (Section-by-Section Analysis)
M304 in the final rule establishes the technical criteria for diagnostic equipment used by patients in a standing position such as a weight scale or x-ray equipment that is used in a standing...
-
Products and services covered under Section 255
Products and services covered under Section 255 FCC rules cover all hardware and software telephone network equipment and telecommunications equipment used in the home or office....
-
A. Chapter 2: M201 Scoping
In the final rule, Chapter 2 establishes that the enforcing authority will determine the number and types of diagnostic equipment to which the MDE Standards will apply....
-
5.4.8 Transfer Support Gripping Surface Hazard for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
5.4.8 Transfer Support Gripping Surface Hazard for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position....
-
M201.1 Enforcing Authority
The proposed standards do not include scoping requirements that specify the minimum number of types of accessible diagnostic equipment required in different types of health care facilities...
- GE Senographe Essential Digital Mammography System
-
M201.1 Enforcing Authority (Section-by-Section Analysis)
The MDE NPRM proposed to explain that the enforcing authority would specify the minimum number of types of accessible diagnostic equipment that would be required to comply with the MDE Standards...
-
Section 1193.33 Information, documentation and training [1193.25 in the NPRM] (Section-by-Section Analysis)
is appropriate for any particular customer....
-
M303.2.4 Equipment Clearances (Section-by-Section Analysis)
A separate set of equipment clearance requirements is necessary to address the unique positioning at mammography equipment....
-
M302.1 General
Where diagnostic equipment is used by patients in a seated position, it shall comply with M302....
- ADA Expert Weighs In On Service at the pump (FuelCall): NBC News Kansas City