H24. Unless the wide stall is located at the end of a row of toilet stalls, does the door to this wider stall open out? [ADA Standards § 4.17.3] Yes No
Search Results "Bus Shelter"
-
H24
-
C. Sidewalks and Walkways
C. Sidewalks and Walkways
-
e-vi
e-vi. Are signs mounted on both sides of the elevator hoist way door opening (for each elevator and at each floor) that designate the floor with 2-inch minimum-height raised letters...
-
J5
J5. Are the controls on or near the front of the unit and do they operate with one hand without tight grasping, pinching, or twisting of the wrist? [ADA Standards §...
-
M18
M18. Is the flush valve located on the side adjacent to the lavatory? [ADA Standards § 4.16.5] Yes No
-
g-ii
g-ii. Is the door hardware (e.g., lever, pull, push, panic bar) usable with one hand, without tight grasping, pinching, or twisting of the wrist, to allow people who may not be able...
-
f-iii
f-iii. Is the ramp width, measured between the handrails, at least 36 inches? [ADA Standards § 4.8.3] Yes No
-
f-i
f-i. Is the running slope no greater than 1:12? [ADA Standards § 4.8.2] Yes No Note: For existing ramps, the slope may be 1:10 for a 6-inch rise and 1:8 for a 3-inch...
-
f-ii
f-ii. Are handrails installed on both sides of each ramp segment? [ADA Standards § 4.8.5] Yes No
-
f-v
f-v. If a ramp is more than 30 feet long, is a level landing at least 60 inches long provided at every 30 feet of horizontal length? [ADA Standards § 4.8.4] Yes ...
-
C1-d
C1-d. Is the accessible route free of steps and abrupt level changes higher than 1/2 inch? [ADA Standards § 4.3.8] Yes No Note: Level changes between 1/4 inch and 1/2...
-
f-i
f-i. Is the lift operational at the time of the survey? [ADA Standards § 4.11.3] Yes No
-
1014.3.1 Surface
The floor surface shall be firm and stable.
-
§ 38.159(a)(2) Exception
meeting the applicable requirements of this section are provided at stations or other stops required to be accessible under regulations issued by the Department of Transportation, the bus...
-
1014.2 Entrance
Camp shelters shall provide an entrance complying with 1014.2.1 or 1014.2.2....
-
1014.2 Entrance
Camp shelters shall provide an entrance complying with 1014.2.1 or 1014.2.2....
-
Americans with Disabilities Act (ADA) Standards for Transportation Facilities
DOT’s ADA Standards apply to facilities used by state and local governments to provide designated public transportation services, including bus stops and stations, and rail stations....
-
A8
Does an accessible route connect the curb ramp to the shelter’s accessible entrance? [ADA Standards § 4.1.2(1)] Yes No...
-
1014.2.1.2 Floor Height
The camp shelter floor at the entrance shall be 19 inches (485 mm) high maximum measured from the clear ground space....
-
1014.2.1.2 Floor Height
The camp shelter floor at the entrance shall be 19 inches (485 mm) high maximum measured from the clear ground space....
-
B9
Does each access aisle connect to an accessible route from the parking area to the shelter's accessible entrance? [ADA Standards § 4.6.2] Yes No...
-
12181(7)(K)
(K) a day care center, senior citizen center, homeless shelter, food bank, adoption agency, or other social service center establishment; and...
-
I5
Is there a sign at each pay phone or pay phone bank for the shelter directing people to the nearest TTY? [ADA Standards § 4.30.7 (3); 4.31.9(3)] Yes No...
-
Requirements to Remember for ADA Compliance in Construction Projects: Transportation Facilities
The ADA Standards issued by the Department of Transportation (DOT) apply to facilities used by state and local governments to provide designated public transportation services, including bus...