Section 407.2.2.1 covers the current ADA Standards for elevator visible and audible signals.
Search Results "Boat Landing"
-
Visible and Audible Signals: ADA Standard Section 407.2.2.1
-
405.9.1 Extended Floor or Ground Surface
The floor or ground surface of the ramp run or landing shall extend 12 inches (305 mm) minimum beyond the inside face of a handrail complying with 505....
-
4.10.4(2)
(2) Visual elements shall be at least 2‒1/2 in (64 mm) in the smallest dimension.
-
405.9.1 Extended Floor or Ground Surface
The floor or ground surface of the ramp run or landing shall extend 12 inches (305 mm) minimum beyond the inside face of a handrail complying with 505....
- Figure 406.4 Landings at the Top of Curb Ramps – Drawing from the U.S. Access Board
-
Is compliance required for parking spaces designed specifically for recreational vehicles such as motor homes and camping or boating trailers?
The ABA Standards, which apply to federally funded sites, provide requirements for outdoor developed areas on federal lands such as camping and picnic facilities that include provisions...
-
405.9.1 Extended Floor or Ground Surface
The floor or ground surface of the ramp run or landing shall extend 12 inches (305 mm) minimum beyond the inside face of a handrail complying with 505....
-
405.9.1 Extended Floor or Ground Surface
The floor or ground surface of the ramp run or landing shall extend 12 inches (305 mm) minimum beyond the inside face of a handrail complying with 505....
-
Elevator Car Requirements [§407.4.2 – §407.4.5]
407.4.2 – §407.4.5] Other requirements for elevator cars include: compliant floor surfaces a maximum 1¼” horizontal clearance between car platform sill and hoistway landing...
-
Section G: Ramps
(§405.5) G5 Does the ramp have a level landing that is at least 60" long, at the top and bottom of each ramp section?...
-
1009.8 Two-way communication
A two-way communication system complying with Sections 1009.8.1 and 1009.8.2 shall be provided at the landing serving each elevator or bank of elevators on each accessible floor that is...
-
1015.2 Where required
Guards shall be located along open-sided walking surfaces, including mezzanines, equipment platforms, aisles, stairs, ramps and landings that are located more than 30 inches (762 mm) measured...
-
1009.8 Two-way communication
A two-way communication system complying with Sections 1009.8.1 and 1009.8.2 shall be provided at the landing serving each elevator or bank of elevators on each accessible floor that is...
-
1013.2 Where required
Guards shall be located along open-sided walking surfaces, including mezzanines, equipment platforms, stairs, ramps and landings that are located more than 30 inches (762 mm) measured vertically...
-
1015.2 Where required
Guards shall be located along open-sided walking surfaces, including mezzanines, equipment platforms, aisles, stairs, ramps and landings that are located more than 30 inches (762 mm) measured...
-
11B-407.2.1.5 Signals
Call buttons shall have visible signals that will activate when each call is registered and will extinguish when each call is answered. Call buttons shall be internally illuminated...
-
8 [§§ 4.3.3; 4.3.7]
8 [§§ 4.3.3; 4.3.7] Curb ramps should have at least 36 inches of clear space at the “top” of the ramp, which can be seen in the illustration to the right [below]. The 36-inch...
-
4.10.4(3)
(3) Signals shall be visible from the vicinity of the hall call button (see Fig. 20). In-car lanterns located in cars, visible from the vicinity of hall call buttons, and conforming...
-
4.10.3 Hall Call Buttons
Call buttons in elevator lobbies and halls shall be centered at 42 in (1065 mm) above the floor. Such call buttons shall have visual signals to indicate when each call is registered...
-
4.10.3 HALL CALL BUTTONS
Call buttons in elevator lobbies and halls shall be centered at 42 in (1065 mm) above the floor. Such call buttons shall have visual signals to indicate when each call is registered...
-
11B-407.2.1.5 Signals
Call buttons shall have visible signals that will activate when each call is registered and will extinguish when each call is answered. Call buttons shall be internally illuminated...
-
11B-407.2.1.5 Signals
Call buttons shall have visible signals that will activate when each call is registered and will extinguish when each call is answered. Call buttons shall be internally illuminated...
-
Ramp Requirements [§405]
Ramp Requirements [§405]
-
1007.8 Two-way communication
A two-way communication system shall be provided at the elevator landing on each accessible floor that is one or more stories above or below the story of exit discharge complying with Sections...