(c) A grab bar at least 24 inches (610 mm) long should be mounted behind the water closet, and a horizontal grab bar at least 40 inches (1015 mm) long should be mounted on at least one side...
Search Results "Bathtub Grab Bar"
-
(1)(c)
-
11B-609.6 Fittings
Grab bars shall not rotate within their fittings....
-
609.6 Fittings
Grab bars shall not rotate within their fittings....
-
609.6 Fittings
Grab bars shall not rotate within their fittings....
-
609.6 Fittings
Grab bars shall not rotate within their fittings....
-
11B-609.6 Fittings
Grab bars shall not rotate within their fittings....
-
Alternate Roll-In Type Shower Compartments: ADA Standard Section 608.3.3
Section 608.3.3 covers the current ADA Standards for grab bars in alternate roll-in type shower compartments.
-
11B-604.8.2.3 Grab bars
Grab bars shall comply with Section 11B-609. A side-wall grab bar complying with Section 11B-604.5.1 shall be provided on both sides of the compartment....
-
609.6 Fittings
Grab bars shall not rotate within their fittings....
-
11B-609.6 Fittings
Grab bars shall not rotate within their fittings....
- Bobrick 48" Straight Grab Bar B-5806 x 48
- Bobrick 48" Straight Grab Bar B-6806 x 48
-
11B-604.8.2.3 Grab bars
Grab bars shall comply with Section 11B-609. A side-wall grab bar complying with Section 11B-604.5.1 shall be provided on both sides of the compartment....
- Gamco 1.5 Inch Diameter Straight Grab Bar with Snap Flange - 150S Series-Snap
- Gamco 1.25 Inch Diameter Straight Grab Bar with Snap Flange - 125S Series - Snap
- Gamco 1.5 Inch Diameter Straight Grab Bar with Concealed Flange - 150C Series-Concealed
-
604.5.1 Side Wall
The side wall grab bar shall be 42 inches (1065 mm) long minimum, located 12 inches (305 mm) maximum from the rear wall and extending 54 inches (1370 mm) minimum from the rear wall....
-
604.5.1 Side Wall
The side wall grab bar shall be 42 inches (1065 mm) long minimum, located 12 inches (305 mm) maximum from the rear wall and extending 54 inches (1370 mm) minimum from the rear wall....
-
§ 38.107(a)(3)
(3) A grab bar at least 24 inches long shall be mounted behind the water closet, and a horizontal grab bar at least 40 inches long shall be mounted on at least one side wall, with one end...
-
11B-604.9.4 Grab bars
Grab bars for water closets shall comply with Section 11B-604.5....
-
11B-604.9.4 Grab bars
Grab bars for water closets shall comply with Section 11B-604.5....
-
American Specialties Snap Flange Concealed Mounting Grab Bar 3700-Series 3D Model
Requires the Premium User plan or above. (Login or upgrade your account!)
-
11B-609.7 Installation
Grab bars shall be installed in any manner that provides a gripping surface at the specified locations and that does not obstruct the required clear floor space....
-
11B-609.7 Installation
Grab bars shall be installed in any manner that provides a gripping surface at the specified locations and that does not obstruct the required clear floor space....