The area within the blue borderlines shall be marked with hatched lines a maximum of 36 inches (914 mm) on center in a color contrasting with that of the aisle surface, preferably blue or...
Search Results "Surface Slope"
Commonly Searched Documents
-
11B-502.3.3 Marking
-
11B-502.3.3 Marking
The area within the blue borderlines shall be marked with hatched lines a maximum of 36 inches (914 mm) on center in a color contrasting with that of the aisle surface, preferably blue or...
-
11B-502.3.3 Marking
The area within the blue borderlines shall be marked with hatched lines a maximum of 36 inches (914 mm) on center in a color contrasting with that of the aisle surface, preferably blue or...
-
R305.1 General
Detectable warning surfaces shall consist of truncated domes aligned in a square or radial grid pattern and shall comply with R305....
-
1005.3.1 Curb or Barrier
Curbs or barriers shall extend 2 inches (51 mm) minimum above the surface of the fishing pier or platform....
-
4.9.4(5)
(5) Top of handrail gripping surface shall be mounted between 34 in and 38 in (865 mm and 965 mm) above stair nosings....
-
4.15.2* Spout Height
Spouts shall be no higher than 36 in (915 mm), measured from the floor or ground surfaces to the spout outlet (see Fig. 27(a))....
-
4.19.6* MIRRORS
Mirrors shall be mounted with the bottom edge of the reflecting surface no higher than 40 in (1015 mm) from the floor (see Fig. 31)....
-
Section E: Route from Entrance
(§303.3) E6 Is the running slope of part of the route greater than 1:20?...
-
Issue 14: Inspection of contractor’s work - Beware of field changes!
Note shifting slopes and cross slopes on the ramps in addition to poor APS location. ...
-
603.3 Mirrors
Mirrors located above lavatories or countertops shall be installed with the bottom edge of the reflecting surface 40 inches (1015 mm) maximum above the finish floor or ground....
-
603.3 Mirrors
Mirrors located above lavatories or countertops shall be installed with the bottom edge of the reflecting surface 40 inches (1015 mm) maximum above the finish floor or ground....
-
903.4 Back Support
Back support shall be 42 inches (1065 mm) long minimum and shall extend from a point 2 inches (51 mm) maximum above the seat surface to a point 18 inches (455 mm) minimum above the seat...
-
11B-603.3 Mirrors
Mirrors located above lavatories or countertops shall be installed with the bottom edge of the reflecting surface 40 inches (1016 mm) maximum above the finish floor or ground....
-
603.3 Mirrors
Mirrors located above lavatories or countertops shall be installed with the bottom edge of the reflecting surface 40 inches (1015 mm) maximum above the finish floor or ground....
-
603.3 Mirrors
Mirrors located above lavatories or countertops shall be installed with the bottom edge of the reflecting surface 40 inches (1015 mm) maximum above the finish floor or ground....
-
4. Summary of Practice
The profile must be represented as a series of elevation values taken along with a series of horizontal distance values along the wheel track. 4.3 The PRI scale starts at zero for a surface...
-
11B-603.3 Mirrors
Mirrors located above lavatories or countertops shall be installed with the bottom edge of the reflecting surface 40 inches (1016 mm) maximum above the finish floor or ground....
-
11B-705.1.1.1 Dome size
Truncated domes in a detectable warning surface shall have a base diameter of 0.9 inch (22.9 mm) minimum and 0.92 inch (23.4 mm) maximum, a top diameter of 0.45 inch (11.4 mm) minimum and...
- Garaventa Evacu-Trac's Brake Can Stop it on the Stairway
-
11B-307.3 Post-mounted objects
Exception: The sloping portions of handrails serving stairs and ramps shall not be required to comply with Section 11B-307.3....
-
406.7 Islands
Each 48 inch (1220 mm) minimum by 36 inch (915 mm) minimum area shall be oriented so that the 48 inch (1220 mm) minimum length is in the direction of the running slope of the curb ramp it...
-
202.6.1
Such measures include but are not limited to providing a ramp with a steeper slope or widening a doorway to a narrower width than that mandated by the alterations requirements....
-
307.3 Post-Mounted Objects
EXCEPTION: The sloping portions of handrails serving stairs and ramps shall not be required to comply with 307.3....