EXCEPTIONS: 1. The top of washing machines and clothes dryers shall be permitted to be 36 inches (915 mm) maximum above the finish floor. 2....
Search Results "Exception"
-
308.3.2 Obstructed High Reach
-
809.2 Residential Dwelling Units with Mobility Features
Exception: * * * * * 809.2.1.1 Location. At least one accessible route shall connect all spaces and elements that are a part of the residential dwelling unit. * * *...
-
5. Comments on Proposed Rule
The comments generally supported the proposed rule, except for the scoping requirements for units with mobility features and units with communication features....
-
703.4.2 Location
EXCEPTION: Signs with tactile characters shall be permitted on the push side of doors with closers and without hold-open devices....
-
703.4.2 Location
EXCEPTION: Signs with tactile characters shall be permitted on the push side of doors with closers and without hold-open devices....
-
604.8.1.4 Toe Clearance
EXCEPTION: Toe clearance at the front partition is not required in a compartment greater than 62 inches (1575 mm) deep with a wall-hung water closet or 65 inches (1650 mm) deep with a floor-mounted...
-
Section-by-Section Analysis
Chapter R4 contains supplementary technical requirements, which are the same as in the 2004 ADA and ABA Accessibility Guidelines with a few exceptions....
-
239.3 Miniature Golf Course Configuration
EXCEPTION: One break in the sequence of consecutive holes shall be permitted provided that the last hole on the miniature golf course is the last hole in the sequence....
-
907.2.8 Group R-1
Exceptions: A manual fire alarm system is not required in buildings not over two stories in height where all individual guestrooms and contiguous attic and crawl spaces are separated...
-
2. Q: Which child care centers are covered by title III?
The exception is child care centers that are actually run by religious entities such as churches, mosques, or synagogues....
-
23. Entire Agreement
This Settlement Agreement cannot be amended, modified or supplemented except by a written document signed by all of the Parties and approved by the District Court....
-
604.8.1.2 Doors
Toilet compartment doors, including door hardware, shall comply with 404 except that if the approach is to the latch side of the compartment door, clearance between the door side of the...
-
Sec. 12150. Interim accessibility requirements. [Section 230]
issued shall suffice to satisfy the requirement that facilities be readily accessible to and usable by persons with disabilities as required under sections 12146 and 12147 of this title, except...
-
206.2.2 Within a Site
EXCEPTION: An accessible route shall not be required between accessible buildings, accessible facilities, accessible elements and accessible spaces if the only means of access between them...
-
12186(d)(1) Facilities
permit is issued shall suffice to satisfy the requirement that facilities be readily accessible to and usable by persons with disabilities as required under section 12183 of this title, except...
-
12165(a) Stations
permit is issued shall suffice to satisfy the requirement that stations be readily accessible to and usable by persons with disabilities as required under section 12162(e) of this title, except...
-
221.4 Designated Aisle Seats
EXCEPTION: Team or player seating areas serving areas of sport activity shall not be required to comply with 221.4. Advisory 221.4 Designated Aisle Seats....
-
11B-606.3 Height
Exceptions: 1. Reserved. [2010 ADAS] 1. ...
-
407.3.4 Door and Signal Timing
EXCEPTIONS: 1....
-
227.2 Check-Out Aisles
EXCEPTION: Where the selling space is under 5000 square feet (465 m2) no more than one check-out aisle complying with 904.3 shall be required....
-
407.11 Keys, Tickets, and Fare Cards (Section-by-Section Analysis)
ICT subject to the 255 Guidelines would be expressly exempted from the requirements of this section (by proposed C204.1 Exception) because telecommunications equipment does not typically...
-
Accessible Transient Lodging [9]
In the case of the private sector, other types of residential facilities, such as apartment buildings, are not subject to the ADA (except for places of public accommodations within them,...
-
308.3.2 Obstructed High Reach
EXCEPTIONS: 1. The top of washing machines and clothes dryers shall be permitted to be 36 inches (915 mm) maximum above the finish floor. 2....
-
Location and Signage
Location and Signage ADAAG does not specify where text telephones are to be located on a site or in a building (except in hospitals, airports, and transit stations)....