be relocated to between 48 inches measured to the baseline of the lowest tactile character and 60 inches measured to the baseline of the highest tactile character above the finish floor surface...
Search Results "Composite Rubber Surface"
Commonly Searched Documents
-
D. Signage
-
A. Accessible Entrance
Accessible Entrance Having a way to get into the emergency shelter on a surface that is firm, stable, slip resistant, without steps or steep slopes, and wide enough for a person using...
-
11B-411.2.1.6 Identification of floors served
consoles located on floors with a building entry, including parking and transfer levels, shall be provided with signage complying with Sections 11B-703.2, 11B-703.3, and 11B-703.5 on the surface...
-
4.4.1 General
In alterations, where a condition for exception in section 1.1 prohibits full compliance with a specific requirement for clear floor or ground space surface, slope, size, or location, the...
-
Conventional Strollers
The small pivoting front wheels on these strollers make them fairly easy to maneuver, but limit their use on unpaved surfaces or rough pavement....
-
11B-411.2.1.6 Identification of floors served
consoles located on floors with a building entry, including parking and transfer levels, shall be provided with signs complying with Sections 11B-703.2, 11B-703.3, and 11B-703.5 on the surface...
-
11B-602.9 Pedestrian protection
When used, wing walls or barriers shall project horizontally at least as far as the drinking fountain and to within 6 inches (152 mm) vertically from the floor or ground surface....
-
11B-1005.2.1 Height
At least 25 percent of the railings, guards, or handrails shall be 34 inches (864 mm) maximum above the ground or deck surface....
-
11B-411.2.1.6 Identification of floors served
consoles located on floors with a building entry, including parking and transfer levels, shall be provided with signs complying with Sections 11B-703.2, 11B-703.3, and 11B-703.5 on the surface...
-
11B-1005.2.1 Height
At least 25 percent of the railings, guards, or handrails shall be 34 inches (864 mm) maximum above the ground or deck surface....
-
Expert Report of John Rife Torkelson, theACCESSpartnership, L.P. (August 8, 2018)
Parking: The surface slope of the designated accessible van space exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.6.3; 2010 ADA Stds 502.4)....
- Sloan WETS 2050.1201-1.28 Solar-Powered HET Flushometer and HET Wall Hung Water Closet
-
Shared Use Paths: ADA Standard Section 2.
address access to sidewalks, streets, and other pedestrian facilities, provide requirements for pedestrian access routes, including specifications for route width, grade, cross slope, surfaces...
-
11B-609.3 Spacing
Section 11B-609.9 the space between the walls and the grab bar shall be 1½ inches (38 mm) minimum for a distance of 6 inches on either side of the inside corner between two adjacent wall surfaces...
-
Expert opinion on the current knowledge
None of the research identified described how well individuals are able to overcome physical barriers in between the wheelchair and target surfaces. ...
-
11B-403.5.1 Clear width
Except as provided in Sections 11B-403.5.2 and 11B-403.5.3, the clear width of walking surfaces shall be 36 inches (914 mm) minimum. Exceptions: 1. ...
-
Grab Bars
Grab bars and any wall or other surfaces adjacent to grab bars must have rounded edges and are not allowed to have sharp or abrasive surfaces....
-
11B-705.1.2.3 Islands or cut-through medians
cut-through less 2 inches (51 mm) maximum on each side, placed at the edges of the pedestrian island or cut-through median, and shall be separated by 24 inches (610 mm) minimum of walking surface...
-
404 Doors, Doorways, and Gates
series (404.2.6) clarify the height of door and gate hardware and add an exception for gates at pools, spas, and hot tubs (404.2.7) revise an exception for door and gate surface...
-
Chapter 4: Accessible Routes
Chapter 4 contains technical requirements for accessible routes (402) and the various components of such routes, including walking surfaces (403), doors, doorways and gates (404), ramps...
-
11B-406.5.12 Detectable warnings
width of the curb ramp (exclusive of flared sides) and shall extend either the full depth of the curb ramp or 24 inches (610 mm) deep minimum measured from the back of the curb on the ramp surface...
-
M303.2.6 Edge Protection (Section-by-Section Analysis)
Protection), the final rule requires platforms with wheelchair spaces that are raised more than 1½ inches in height to provide a minimum 2-inch-high edge protection, measured from the surface...
-
Maximum Slope at Ground Level
A berm may be a natural sloped surface that is present in a hilly play area site, or a ground-level route built with slopes....
-
606.3 Height
Lavatories and sinks shall be installed with the front of the higher of the rim or counter surface 34 inches (865 mm) maximum above the finish floor or ground. EXCEPTIONS: 1....