Medical care facilities included in this section are those in which people receive physical or medical treatment or care and where persons may need assistance in responding to an...
Search Results "Accessibility Standard"
Commonly Searched Documents
-
6.1 General
-
6.8.2 Grade and cross slope
The slope of a resting interval shall not be steeper than 1:33 (3 percent) in any direction. Where the surface is paved or is elevated above the natural ground, the surface shall not...
-
3.2.5.1 Walk-In Camping
Where walk-in camping is provided, an ORAR connecting the camp living area to the parking area shall be provided in accordance with section 2.0.
-
2.2 Surface
The surface of an ORAR shall be firm and stable. The type of surface should be appropriate to the setting and level of development.
-
6.1 GENERAL
In addition to the requirements of 4.1 to 4.33, Health Care buildings and facilities shall comply with 6.
-
1018.8.2 Slope
This section requires the slope of resting intervals to not be steeper than 1:48 in any direction. Where the surface is other than asphalt, concrete, or boards, slopes not steeper...
-
2.5.1 Location
A resting interval shall be provided between each ORAR segment, in compliance with section 2.4.1. Depending on the design and location, the intersection of two ORARs may act as a...
-
2.4.2 Cross Slope
The cross slope of an ORAR shall be no more than 1:33 (3 percent). Where the surface is paved or is elevated above the natural ground, the cross slope shall not be steeper than 1:48...
-
Door Pressure Gauge
Door Pressure Gauge This Door Pressure Gauge, available from Evan Terry Associates, measures forces from 0-35 pounds on one side and 0-16 kilograms on the other. If you do not...
-
Double Action Door Pressure Gauge
Double Action Door Pressure Gauge This Door Pressure Gauge, available from Evan Terry Associates, has Push-Pull capability and measures forces from 0-35 pounds on one side and...
-
1018.8.2 Slope
Resting intervals shall have a slope not steeper than 1:48 in any direction. EXCEPTION: Where the surface is other than concrete, asphalt, or boards, cross slopes not steeper than...
-
1014.2.1.1.1 Surface
The surface of the clear ground space shall be firm and stable.
-
1016.7.2 Cross Slope
The cross slope shall not be steeper than 1:48. EXCEPTION: Where the surface is other than concrete, asphalt, or boards, cross slopes not steeper than 1:20 shall be permitted when...
-
Where can one get further information or technical assistance on the IBC, including its requirements for means of egress?
Technical assistance on the IBC is available from the International Code Council (ICC) at (888) ICC-SAFE (422-7233) or by email at CareCenter@iccsafe.org . For further information,...
-
Requirements for Platform Lifts
Platform Lift Clear Floor Space and Doors/ Gates
-
1009.8.1.1 Visible communication method
[DSA-AC and HCD 1-AC] A button complying with Section 1138A.4 or Sections 11B-205 and 11B-309 _|Operable Parts|_ in the area of refuge shall activate both a light in the area of...
-
Colorado Cross-Disability Coalition, et al. Plaintiffs, v. Abercrombie & Fitch Co., et al., Defendants. - Statement of Interest on the Parties' Motions for Summary Judgment
IN THE UNITED STATES DISTRICT COURT FOR THE DISTRICT OF COLORADO Civil Action No. 09-cv-02757-WYD-KMT COLORADO CROSS-DISABILITY COALITION, et...
-
11B-604.8.1.4 Toe clearance
11B-604.8.1.4 Toe clearance. At least one side partition shall provide a toe clearance of 9 inches (229 mm) minimum above the finish floor and 6 inches (152 mm) deep minimum beyond...
-
1009.6.5 Two-way communication
Areas of refuge shall be provided with a two-way communication system complying with Sections 1009.8.1 and 1009.8.2.
-
1009.6.5 Two-way communication
Areas of refuge shall be provided with a two-way communication system complying with Sections 1009.8.1 and 1009.8.2.
-
11B-809.7.2 Changes in level
Changes in level shall comply with Sections 11B-303.2 and 11B-303.3. Ramps complying with Section 11B-405, elevators complying with Section 11B-407 or platform lifts complying with...
-
1009.8.1.1 Visible communication method
[DSA-AC and HCD 1-AC] A button complying with Section 1138A.4 or Sections 11B-205 and 11B-309 in the area of refuge shall activate both a light in the area of refuge indicating that...
-
F245.4.4 Location
Outdoor recreation access routes required by F245.4.2 and F245.4.3 shall coincide with or be located in the same area as general circulation paths. Advisory F245.4.4 Location....
-
1018.4 Clear Width
This section requires the clear width of beach access routes to be 60 inches minimum to enable individuals who use wheeled mobility devices to pass beach visitors traveling in the opposite...