All or any portion of aircraft, buildings, structures, equipment, roads, walks, parking lots, and any other real or personal property, normally used by passengers or prospective passengers...
Search Results "Model Building Code"
-
Facility:
- HEWI Panic Bar EN 1125
- Pilot Rock BS Series Bike Stand
-
1.3 Architectural Standards.
However, each contains a few unique provisions, which are included in the 2010 edition of the standards. http://www.access214board.gov/guidelines-and-standards/buildings-and-sites/about-the-ada-standards...
-
Accessible Routes to Press Boxes
Section 201.1 of the 2010 Standards requires that all areas of newly designed and constructed buildings and facilities and altered portions of existing buildings and facilities be accessible...
-
IX. New Construction
The new construction requirements apply to any facility occupied after January 26, 1993, for which the last application for a building permit or permit extension is certified as complete...
-
405.2 Slope
EXCEPTION: In existing sites, buildings, and facilities, ramps shall be permitted to have running slopes steeper than 1:12 complying with Table 405.2 where such slopes are necessary due...
-
Technical Memorandum TM 2012-03 Shopping Centers or Shopping Malls
TM 2012-03 Shopping Centers or Shopping Malls Effective Date:Â November 15, 2012 2012 TAS Reference:Â 206.2.3, Exception 1;Â 206.2.4, Exception 3Â If a private building or facility...
-
405.2 Slope
EXCEPTION: In existing sites, buildings, and facilities, ramps shall be permitted to have running slopes steeper than 1:12 complying with Table 405.2 where such slopes are necessary due...
-
Orientation (slide 12)
We don’t always do that in public spaces, and we don’t always do that even in office buildings....
-
Seat Heights
ADA-ABA Accessibility Guidelines for Buildings and Facilities (ADA-ABA). 2002. http://www.access-board.gov/guidelines-and-standards/buildings-and-sites/about-the-ada-standards/background...
-
Seat width and depth
ADA-ABA Accessibility Guidelines for Buildings and Facilities (ADA-ABA). 2002. http://www.access-board.gov/guidelines-and-standards/buildings-and-sites/about-the-ada-standards/background...
-
405.2 Slope
EXCEPTION: In existing sites, buildings, and facilities, ramps shall be permitted to have running slopes steeper than 1:12 complying with Table 405.2 where such slopes are necessary due...
-
Step One: Accessible Shelter Quick-Check Survey
For some older buildings, especially those on hilly sites and those that have not been renovated, remodeled, or altered since 1992, before completing the detailed checklist, it may be better...
-
Rough Grade Site Inspection
SITE INSPECTION Locate and verify the plan specified accessible routes from existing public sidewalks, accessible parking locations, and other site arrival points to building...
-
A4.30.1 GENERAL
In building complexes where finding locations independently on a routine basis may be a necessity (for example, college campuses), tactile maps or prerecorded instructions can be very helpful...
-
Rough Grade Site Inspection
SITE INSPECTION Locate and verify the plan specified accessible routes from existing public sidewalks, accessible parking locations, and other site arrival points to building...
-
1009.7.2 Separation
Exterior walls separating the exterior area of assisted rescue from the interior of the building shall have a minimum fire-resistance rating of 1 hour, rated for exposure to fire from the...
- TownSteel TDC 90 ALUMINUM Grade 1 Door Closer
- Symmetry Vertical Platform Lift VPC-SL
- AJW Architectural Products UG2-Railing UG2X-Y108 108" Concealed Snap Flange, 1.25" Diameter, Peened Grip - Configuration Y
- AJW Architectural Products UG3-A Series UG3-A12 12" Concealed Snap Flange, 1.5" Diameter Grab Bar - Configuration A
- AJW Architectural Products UG30-Railing UG30X-Y108 108" Concealed Set Screw Flange, 1.5" Diameter, Peened Grip - Configuration Y
- AJW Architectural Products UG20-Railing UG20X-Y108 108" Concealed Set Screw Flange, 1.25" Diameter, Peened Grip - Configuration Y