Detectable warnings are walking surfaces that are primarily intended to provide a tactile cue to pedestrians who are visually impaired....
Search Results "Surface Smoothness"
Commonly Searched Documents
-
Executive Summary
-
10 [§ 4.7.5]
A curb ramp may have returned curbs if it has non-walking surfaces (such as grass) or obstructions on both sides because these conditions would normally discourage pedestrians from walking...
-
11B-1005.2.1 Height
At least 25 percent of the railings, guards, or handrails shall be 34 inches (864 mm) maximum above the ground or deck surface....
-
1003.2.12.1 Height
Guards shall form a protective barrier not less than 42 inches (1067 mm) high, measured vertically above the leading edge of the tread, adjacent walking surface or adjacent seatboard....
-
Handrails
The top of the handrail gripping surface must be a minimum of 34 inches and a maximum of 38 inches above the stair nosing....
-
Accessible Routes
The accessible route must comply with ADAAG provisions for the location, width (minimum of 36 inches), passing space,head room, surface, slope (maximum of 1:12 or 8.33%), changes in level...
-
Openings, Width and Length of Wheelchair Space
Wheelchair spaces must have a clear width of 30 inches minimum and a clear length of 48 inches minimum, measured to at least 9 inches above the floor surface....
-
Will CALGreen be amended to require that some parking spaces are designed so that they can comply with Chapter 11B requirements when converted to EV charging spaces (i.e. slope, vertical clearance, path of travel)?
provide an electrical raceway to the service panel, and provide adequate capacity at the service panel for future EVCS; good design practice would be to incorporate appropriate ground surfaces...
-
R209.1 General
., audible tones and vibrotactile surfaces) to pedestrians who are blind or have low vision....
-
Wheelchair seating locations must provide lines of sight comparable to those provided to other spectators.
A comparable line of sight, as illustrated in the figure below, allows a person using a wheelchair to see the playing surface between the heads and over the shoulders of the persons standing...
-
1003.2.12.1 Height
Guards shall form a protective barrier not less than 42 inches (1067 mm) high, measured vertically above the leading edge of the tread, adjacent walking surface or adjacent seatboard....
-
D. Signage
be relocated to between 48 inches measured to the baseline of the lowest tactile character and 60 inches measured to the baseline of the highest tactile character above the finish floor surface...
-
A. Accessible Entrance
Accessible Entrance Having a way to get into the emergency shelter on a surface that is firm, stable, slip resistant, without steps or steep slopes, and wide enough for a person using...
-
11B-411.2.1.6 Identification of floors served
consoles located on floors with a building entry, including parking and transfer levels, shall be provided with signage complying with Sections 11B-703.2, 11B-703.3, and 11B-703.5 on the surface...
-
4.4.1 General
In alterations, where a condition for exception in section 1.1 prohibits full compliance with a specific requirement for clear floor or ground space surface, slope, size, or location, the...
-
Conventional Strollers
The small pivoting front wheels on these strollers make them fairly easy to maneuver, but limit their use on unpaved surfaces or rough pavement....
-
11B-411.2.1.6 Identification of floors served
consoles located on floors with a building entry, including parking and transfer levels, shall be provided with signs complying with Sections 11B-703.2, 11B-703.3, and 11B-703.5 on the surface...
-
11B-602.9 Pedestrian protection
When used, wing walls or barriers shall project horizontally at least as far as the drinking fountain and to within 6 inches (152 mm) vertically from the floor or ground surface....
-
11B-1005.2.1 Height
At least 25 percent of the railings, guards, or handrails shall be 34 inches (864 mm) maximum above the ground or deck surface....
-
11B-1005.2.1 Height
At least 25 percent of the railings, guards, or handrails shall be 34 inches (864 mm) maximum above the ground or deck surface....
-
11B-411.2.1.6 Identification of floors served
consoles located on floors with a building entry, including parking and transfer levels, shall be provided with signs complying with Sections 11B-703.2, 11B-703.3, and 11B-703.5 on the surface...
-
Expert Report of John Rife Torkelson, theACCESSpartnership, L.P. (August 8, 2018)
Parking: The surface slope of the designated accessible van space exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.6.3; 2010 ADA Stds 502.4)....
- Harmar P300 Pool Lift