As a result, toilet room configuration and location of the water closet were the critical design considerations in assisted transfers....
Search Results "Securement Location"
-
4.16.2 Clear Floor Space
-
4.5.1 General
In alterations, where a condition for exception in section 1.1 prohibits full compliance with a specific requirement for clear floor or ground space surface, slope, size, or location, the...
-
What constitutes a “passenger loading zone”?
At other locations, compliance is not required even if passenger loading may occasionally occur, but is not specifically intended or reflected in the design....
-
11B-604.7.1 Dispensers
The outlet of the dispenser shall be below the grab bar, 19 inches (483 mm) minimum above the finish floor and shall not be located behind grab bars....
-
11B-806.3.2 Notification devices
Telephones shall be served by an electrical outlet complying with Section 11B-309 located within 48 inches (1219 mm) of the telephone to facilitate the use of a TTY....
-
11B-806.3.2 Notification devices
Telephones shall be served by an electrical outlet complying with Section 11B-309 located within 48 inches (1219 mm) of the telephone to facilitate the use of a TTY....
-
11B-307.4 Vertical clearance
The leading edge of such guardrail or barrier shall be located 27 inches (686 mm) maximum above the finish floor or ground....
-
11B-604.7.1 Dispensers
The outlet of the dispenser shall be below the grab bar, 19 inches (483 mm) minimum above the finish floor and shall not be located behind grab bars....
-
11B-703.6.1 Pictogram field
Characters and Braille shall not be located in the pictogram field. Advisory 11B-703.6.1 Pictogram field....
-
11B-606.6 Adjacent side wall or partition
Lavatories, when located adjacent to a side wall or partition, shall be a minimum of 18 inches (457 mm) to the centerline of the fixture....
-
307.4 Vertical Clearance
The leading edge of such guardrail or barrier shall be located 27 inches (685 mm) maximum above the finish floor or ground....
-
1009.3.2 Submerged Depth
Where landings are required by 405.7, at least one landing shall be located 24 inches (610 mm) minimum and 30 inches (760 mm) maximum below the stationary water level....
- Bradley Sensor-Operated Soap Dispenser 6315
- Honeywell Fire-Lite Alarm BG-12 Series
- Neo-Metro Commercial Metaal Toilet 8956 Series
- Pilot Rock Smoker's Stack Ash Tray
- EZ-ACCESS Transitions® Modular Entry Ramp
- Inclusion Solutions Freestanding Totem Pocket Display
- SignOnVRI Video Remote Interpreting
- Neo-Metro Contour Commercial Stainless Steel Toilet 8955 Series
-
11B-806.2.4 Toilet and bathing facilities
Toilet and bathing fixtures required to comply with Sections 11B-603 through 11B-610 shall be permitted to be located in more than one toilet or bathing area, provided that travel between...
-
Alterations to Individual Residential Dwelling Units: ADA Standard Section 233.3.4.2
Section 233.3.4.2 covers scoping requirements in the current ADA Standards for alterations to individual residential dwelling units.
-
11B-1007.2 Accessible routes
Accessible routes located on playing surfaces of miniature golf holes shall be permitted to use the exceptions in Section 11B-1007.2....
-
Integration: ADA Standard Section 221.2.2
Section 221.2.2 covers scoping requirements in the current ADA Standards for integration of wheelchair spaces in assembly areas.