If there is a choice between flooring materials otherwise suitable for a particular application, we recommend choosing the material with the higher coefficient of friction, particularly...
Search Results "Floor Destination Indicator"
-
What materials may satisfy ADAAG requirements?
-
Camp Shelters
The long side of the clear floor or ground space must be parallel to the camp shelter entrance....
- Adaptive Engineering Inc. Mobilift TX Wheelchair Lift for Rail Access
-
1.14 Riser
1.14 "Riser" shall mean and refer to an elevated tier (usually six to eighteen inches) in an auditorium on which seats are affixed to the auditorium floor....
-
4. Toilet seat height
Toilet seat height: The toilet seat needs to be from 17 to 19 inches above the floor to permit transfers to and from wheelchairs....
-
Question 20
Is the required floor and wall space inside public restrooms and fitting rooms blocked by obstacles such as trash cans, chairs, or shelving?...
-
J3
Is the top of the spout no higher than 36 inches above the floor and at the front of the fountain or water cooler? [ADA Standards § 4.15.2] Yes No...
-
I. Toilet Seat
Is the toilet seat at each accessible toilet between 17"-19" above the floor? [ADA Stds. 4.16.3] Yes __ No __ N/A __ Comments: ___________________________________________...
-
4.15.2* Spout Height
Spouts shall be no higher than 36 in (915 mm), measured from the floor or ground surfaces to the spout outlet (see Fig. 27(a))....
-
5.1.4 Turning Space
Where the camp shelter floor is not elevated above the trail or ORAR, as applicable, a turning space complying with ABAAS section 304.3 shall be provided....
-
4.19.6* MIRRORS
Mirrors shall be mounted with the bottom edge of the reflecting surface no higher than 40 in (1015 mm) from the floor (see Fig. 31)....
-
M303.2.4.1 Toe Clearance
Toe clearance shall be provided at a height of 9 inches (230 mm) above the floor to a depth of 6 inches (150 mm) maximum....
-
11B-604.7 Dispensers and disposal units
The outlet of the dispenser shall be 15 inches (380 mm) minimum and 48 inches (1220 mm) maximum above the finish floor and shall not be located behind grab bars....
-
11B-604.7 Dispensers and disposal units
The outlet of the dispenser shall be 15 inches (380 mm) minimum and 48 inches (1220 mm) maximum above the finish floor and shall not be located behind grab bars....
-
Text Telephones (TTYs) (Advisory Guidance)
Make sure there is a dial tone by checking for a steady light on the TTY status indicator. d....
-
11B-703.5.5 Character height
Exception: Where provided, floor plans providing emergency procedures information in accordance with Title 19 shall not be required to comply with Section 11B-703.5.5....
-
11B-809.10.2 Number of complying bathing rooms and fixtures
Within dormitories in housing at a place of education, dormitory floors served by an accessible route and providing only sleeping rooms complying with 11B-809.6, and where bathrooms are...
-
11B-608.6 Shower spray unit and water
One shower head shall be located at a height of 48 inches (1219 mm) maximum above the shower finish floor....
-
11B-608.6 Shower spray unit and water
One shower head shall be located at a height of 48 inches (1219 mm) maximum above the shower finish floor....
-
11B-703.5.5 Character height
Exception: Where provided, floor plans providing emergency procedures information in accordance with Title 19 shall not be required to comply with Section 11B-703.5.5....
-
11B-809.10.2 Number of complying bathrooms and fixtures
Within dormitories in housing at a place of education, dormitory floors served by an accessible route and providing only sleeping rooms complying with 11B-809.6, and where bathrooms are...
-
11B-604.8.1.2 Doors
Doors shall not swing into the clear floor space or clearance required for any fixture....