All intercity rail stations shall be made readily accessible to and usable by individuals with disabilities, including individuals who use wheelchairs, as soon as practicable, but in...
Search Results "Wheelchair Location"
-
§ 37.55 Intercity rail station accessibility
-
Issue 8: Rest-in-WALK (quiet time ok)
Issue 8: Rest-in-WALK (quiet time ok) In some locations, the pedestrian signals ‘rest-in-WALK’ and it may not be desirable to have the WALK indication repeat constantly during the long...
-
5.3.2 Transfer Sides Recommendations for M301
5.3.2 Transfer Sides Recommendations for M301 Description: The transfer side provision requires the transfer surface to be located to provide options to transfer onto the short side and...
-
11B-608.5.2 Standard roll-in type shower compartments
In standard roll-in type shower compartments, the controls, faucets, and the shower spray unit shall be located on the back wall of the compartment adjacent to the seat 16 inches (406 mm...
-
Measuring Techniques
The user touches the probe on a body landmark, presses a button, and the location of the point in three-dimensional space is recorded automatically in the computer software....
- Magnuson Group VESUVIO Ash Trays
-
9.2.2(1)
(1) Accessible sleeping rooms shall have a 36 in (915 mm) clear width maneuvering space located along both sides of a bed, except that where two beds are provided, this requirement can be...
-
Toilet Paper Dispensers
measured to the centerline of the dispenser.The paper outlet of the dispenser must be located 15 inches minimum and 48 inches maximum above the finish floor....
-
11B-608.5.2 Standard roll-in type shower compartments
and faucets shall be installed on the back wall of the compartment adjacent to the seat wall 19 inches (483 mm) minimum and 27 inches (686 mm) maximum from the seat wall; and shall be located...
-
608.5.2 Standard Roll-In Type Shower Compartments
In standard roll-in type shower compartments, the controls, faucets, and shower spray unit shall be located above the grab bar, but no higher than 48 inches (1220 mm) above the shower floor...
-
608.5.3 Alternate Roll-In Type Shower Compartments
In alternate roll-in type shower compartments, the controls, faucets, and shower spray unit shall be located above the grab bar, but no higher than 48 inches (1220 mm) above the shower floor...
-
11B-803.5 Coat hooks and shelves
Coat hooks provided within the room shall be located within one of the reach ranges specified in Section 11B-308....
-
11B-809.10.5.1 Clear floor space
A clear floor space 30 inches (762 mm) minimum by 48 inches (1219 mm) minimum shall be located with the long edge of the clear floor space parallel to the side of the bathtub or bathtub-shower...
-
GRAB BAR
A grab bar may also provide support for a user transferring from a wheelchair onto a bench, seat or plumbing fixture. ◼...
-
F. Counter Height
Do the registration counters or other counters serving guests have a lowered portion no more than 36" high or is there a folding shelf at 36" high to allow persons who use wheelchairs to...
-
G. Self-serve Items
If a counter is used for serving breakfast or other food products, does it have at least a 36" long section that is no higher than 36" above the floor to allow persons who use wheelchairs...
-
Sec. 12146. New facilities. [Section 226]
used in the provision of designated public transportation services unless such facility is readily accessible to and usable by individuals with disabilities, including individuals who use wheelchairs...
-
7. Grab Bars
Are there two horizontal grab bars (one high/one low) along the side of the tub that are at least 24" long for stabilization and aid in transfer from a wheelchair to the fixed tub seat -...
-
12184(b)(6)
solicitation is made later than 30 days after the effective date of this paragraph, that is not readily accessible to and usable by individuals with disabilities, including individuals who use wheelchairs...
-
§35.135 Personal devices and services
This part does not require a public entity to provide to individuals with disabilities personal devices, such as wheelchairs; individually prescribed devices, such as prescription eyeglasses...
-
Scoping [4.1.3(17)(a) & (b)]
Scoping [4.1.3(17)(a) & (b)] ADAAG addresses public telephones (pay, closed circuit) that are fixed and requires access for people who use wheelchairs and for people who are deaf,...
-
4.3.3 WIDTH
If a person in a wheelchair must make a turn around an obstruction, the minimum clear width of the accessible route shall be as shown in Fig. 7....
-
9.3 SELF-SERVICE POSTAL CENTER
All mechanisms must be installed to permit close parallel approach by a wheelchair user....
-
407.2.1.1 Height
Call buttons and keypads shall be located within one of the reach ranges specified in 308, measured to the centerline of the highest operable part....