This unit provides ADA compliant undersink protection by meeting mandated knee and toe clearance requirements for wheelchair users....
Search Results "Wheelchair Location"
Commonly Searched Documents
- Behavioral Safety Products #TC230 Suicide Resistant Standard Trap Cover
- Sargent AD8400 & NB-AD8400 Narrow Stile Concealed Vertical Rod Exit Device
- ADA Sign Depot Men's Accessible Restroom Wall Sign with Tactile Text and Grade 2 Braille - 6" x 8"
-
1.3.1 Overview of NPRM
(M303) Wheelchair space, including orientation, width, depth, knee and toe clearance, and surface slope Changes in level at entry to wheelchair space, including ramps...
-
Floor Designations
In the final rule, this specification, now located at section 407.2.3.1, applies the mounting height generally required for other types of tactile signs by 703.2 (48 to 60 inches above the...
-
407.12.2.2 Obstructed Side Reach
Where the operable part is located more than 10 inches (255 mm), but not more than 24 inches (610 mm), beyond the vertical reference plane, the height of the operable part shall be 46 inches...
-
11B-233.3.1.2.4 Multi-story residential dwelling units in buildings with one or more elevators
At least one powder room or bathroom and kitchen shall be located on the primary entry level....
- Rebuilding Together Nashville - Nashville, TN
- Allegion aptiQmobile Credentials Mobile Application
-
§382.51(a)(1)
(1) You must ensure that terminal facilities providing access to air transportation are readily accessible to and usable by individuals with disabilities, including individuals who use wheelchairs...
-
Lawn Seating
Since such areas typically do not provide fixed seating, this provision does not require wheelchair spaces, companion seats, or designated aisle seats....
-
§382.41(c)
You must provide this information to any passenger who states that he or she uses a wheelchair for boarding, even if the passenger does not explicitly request the information....
-
2-3. Amend § 35.104
Standards, 2004 ADAAG, direct threat, existing facility, other power-driven mobility device, proposed standards, service animal, qualified reader, video interpreting services (VIS), and wheelchair...
-
E. Key Reach Range
If there is key card controlled door hardware on building entrances, is the key card reader positioned so persons who use wheelchairs may approach and operate the opener (48" high maximum...
-
12162(e)(1) New stations
to build a new station for use in intercity or commuter rail transportation that is not readily accessible to and usable by individuals with disabilities, including individuals who use wheelchairs...
-
407.12.1.1 Vertical Plane for Side Reach (Section-by-Section Analysis)
The 48-inch dimension is based on the length of a stationary occupied wheelchair. This side reach requirement mirrors existing 508 Standards § 1194.25(j)(1) and Figure 1....
-
4.1.6(3)(c)(iii)
For example, an elevator of 47 in by 69 in (1195 mm by 1755 mm) with a door opening on the narrow dimension, could accommodate the standard wheelchair clearances shown in Figure 4....
-
5b.
Does the floor area of the elevator car provide space for wheelchair users to enter, reach the controls, and exit the car?...
-
5.2 Offer Suggestions
For example, you might say, “If you remove two chairs from the waiting room, it would be much easier for a wheelchair user to wait in and to get through the area.”...
-
4.2.6* Side Reach
If the clear floor space allows parallel approach by a person in a wheelchair, the maximum high side reach allowed shall be 54 in (1370 mm) and the low side reach shall be no less than 9...
-
A4.11 PLATFORM LIFTS
Platform lifts include porch lifts and other devices used for short-distance, vertical transportation of people in wheelchairs....
-
A4.34.6.7 OVENS
Countertop or wall-mounted ovens with side-opening doors are easier for people in wheelchairs to use....
-
Islands [§406.7]
Islands [§406.7] A 48” min. long separation is necessary between curb ramps so that people using wheelchairs can clear one ramp before negotiating the next....
-
§ 38.113(a)(2)
extent practicable in accordance with regulations issued under the Federal Railroad Safety Act of 1970 (49 CFR parts 229 and 231), shall have a clear opening width of 32 inches to permit wheelchair...