A circle, ¼ inch (6.4 mm) thick and 12 inches (305 mm) in diameter, shall be located at entrances to women’s toilet and bathing facilities....
Search Results "Shall"
Commonly Searched Documents
-
11B-703.7.2.6.2 Women’s toilet and bathing facilities
-
605.4 Flush Controls
Flush controls shall be hand operated or automatic. Hand operated flush controls shall comply with 309....
-
11B-802.3.2 Type
Companion seats shall be equivalent in size, quality, comfort, and amenities to the seating in the immediate area. Companion seats shall be permitted to be movable....
-
505.8 Surfaces
Handrail gripping surfaces and any surfaces adjacent to them shall be free of sharp or abrasive elements and shall have rounded edges....
-
11B-409.2 Call buttons
Call buttons shall be ¾ inch (19.1 mm) minimum in the smallest dimension and shall comply with Section 11B-309 _|Operable Parts|_....
-
11B-704.2.2 Operable parts
Operable parts shall comply with Section 11B-309. Telephones shall have push-button controls where such service is available....
-
11B-409.4.6 Car controls
Elevator car control buttons shall comply with Sections 11B-409.4.6, 11B-309.3, 11B-309.4, and shall be raised or flush....
-
802.3.2 Type
Companion seats shall be equivalent in size, quality, comfort, and amenities to the seating in the immediate area. Companion seats shall be permitted to be movable....
-
705.1 General
Detectable warnings shall consist of a surface of truncated domes and shall comply with 705. Figure 705.1 Size and Spacing of Truncated Domes...
-
703.2.3 Style
Characters shall be sans serif. Characters shall not be italic, oblique, script, highly decorative, or of other unusual forms....
-
F240.2.1.1 Minimum Number and Types
Where ground level play components are provided, at least one of each type shall be on an accessible route and shall comply with 1008.4....
-
M302.3.1 Transfer Supports
Transfer supports shall be provided for use with transfer sides required by M302.2.4 and shall comply with M305.2.1.1, M305.2.2.1, and M305.2.3 through M305.2.8....
-
11B-408.3.2 Swinging doors
Swinging hoistway doors shall open and close automatically and shall comply with Sections 11B-404, 11B-407.3.2 and 11B-408.3.2....
-
802.3.2 Type
Companion seats shall be equivalent in size, quality, comfort, and amenities to the seating in the immediate area. Companion seats shall be permitted to be movable....
-
604.8.2.3 Grab Bars
Grab bars shall comply with 609. A side-wall grab bar complying with 604.5.1 shall be provided on both sides of the compartment....
-
703.6.1 Pictogram Field
Pictograms shall have a field height of 6 inches (150 mm) minimum. Characters and braille shall not be located in the pictogram field....
-
303.4 Ramps
Changes in level greater than 1/2 inch (13 mm) high shall be ramped, and shall comply with 405 or 406....
-
604.8.2.3 Grab Bars
Grab bars shall comply with 609. A side-wall grab bar complying with 604.5.1 shall be provided on both sides of the compartment....
-
F202.2.2 Entrance
Where an entrance is not provided in an addition, at least one entrance in the existing building or facility shall comply with F206.4 and shall serve the addition....
-
505.8 Surfaces
Handrail gripping surfaces and any surfaces adjacent to them shall be free of sharp or abrasive elements and shall have rounded edges....
-
240.2.1.1 Minimum Number and Types
Where ground level play components are provided, at least one of each type shall be on an accessible route and shall comply with 1008.4....
-
R410.4 Style
Characters shall be conventional in form. Characters shall not be italic, oblique, script, highly decorative, or of other unusual forms....
-
T207.1 General
Non-rail vehicles shall provide handrails, stanchions, and handholds in accordance with T207. Handrails, stanchions, and handholds shall comply with T303....
-
T207.3 Fare Collection Devices
Handrails shall be provided at fare collection devices and shall be configured so that they can be used for support when at the fare collection device....