SECTION 1124B - GROUND AND FLOOR SURFACES 1124B.1 General. ...
Search Results "Floor Surface"
-
1118B.3
-
11B-707.7.1.1 Vertically mounted display screen
mounted vertically or no more than 30 degrees tipped away from the viewer, the center line of the display screen and other display devices shall be no more than 52 inches (1321 mm) above the floor...
-
6.5
6.5 Each wheelchair space shall comply with the size requirements set forth in § 4.33.2 of the Standards, be level and satisfy the floor surface requirements as set forth in § 4.33.4...
-
11B.707.7.1.2 Angle-mounted display screen
mounted between 30 degrees and 60 degrees tipped away from the viewer, the center line of the display screen and other display devices shall be no more than 44 inches (1118 mm) above the floor...
-
11B.707.7.1.1 Vertically mounted display screen
mounted vertically or tipped away from the viewer less than 30 degrees, the center line of the display screen and other display devices shall be no more than 52 inches (1321 mm) above the floor...
-
308.3.1 Unobstructed
reach shall be 15 inches (380 mm) minimum above the finish floor or ground....
-
308.3.1 Unobstructed
reach shall be 15 inches (380 mm) minimum above the finish floor or ground....
-
308.3.1 Unobstructed
reach shall be 15 inches (380 mm) minimum above the finish floor or ground....
-
11B-308.3.1 Unobstructed
reach shall be 15 inches (381 mm) minimum above the finish floor or ground. ...
-
M302.4.1 Clearance in Base
The base of the diagnostic equipment shall provide a clearance 39 inches (990 mm) wide minimum, 6 inches (150 mm) high minimum measured from the floor, and 36 inches (915 mm) deep minimum...
-
M301.4.1 Clearance in Base
The base of diagnostic equipment shall provide a clearance 39 inches (990 mm) wide minimum, 6 inches (150 mm) high minimum measured from the floor, and 36 inches (915 mm) deep minimum measured...
-
M302.4.1 Clearance in Base
The base of the equipment shall provide a clearance 44 inches (1120 mm) wide minimum, 6 inches (150 mm) high minimum measured from the floor, and 36 inches (915 mm) deep minimum measured...
-
M301.4.1 Clearance in Base
The base of the equipment shall provide a clearance 44 inches (1120 mm) wide minimum, 6 inches (150 mm) high minimum measured from the floor, and 36 inches (915 mm) deep minimum measured...
-
ALIGNMENT OF 19-INCH RECOMMENDATION WITH ACCESS BOARD PROPOSED RULEMAKING
from the floor to the top of the transfer surface” for both examination tables and chairs.5 The Access Board based its proposal, “on provisions in the 2004 ADA and ABA Accessibility Guidelines...
-
1002.5 Amusement Ride Seats Designed for Transfer
The proximity of the clear floor or ground space next to an element and the height of the element one is transferring to are both critical for a safe and independent transfer....
-
11B-606.3 Height
Lavatories and sinks shall be installed with the front of the higher of the rim or counter surface 34 inches (864 mm) maximum above the finish floor or ground....
-
11B-606.3 Height
Lavatories and sinks shall be installed with the front of the higher of the rim or counter surface 34 inches (864 mm) maximum above the finish floor or ground....
-
11B-606.3 Height
Lavatories and sinks shall be installed with the front of the higher of the rim or counter surface 34 inches (864 mm) maximum above the finish floor or ground....
- Rebuilding Together Of the Triangle - Raleigh, NC
-
3.13(a) Placement of Wheelchair Spaces
Placement of Wheelchair Spaces Each wheelchair space shall comply with the size requirements set forth in § 4.33.2 of the Standards, be level and satisfy the floor surface requirements...
-
1132A.4, Item 1
., concrete, brick, flagstone) serving primary entry doors and required exit doors are limited to not more than ½ inch (12.7 mm) of change in height between floor surfaces....
-
1132A.4, Item 1
., concrete, brick, flagstone) serving primary entry doors and required exit doors are limited to not more than ½ inch (12.7 mm) of change in height between floor surfaces....
-
11B.707.7.1.3 Horizontally mounted display screen
from the viewer 60 degrees to 90 degrees (horizontal) from vertical, the center line of the display screen and other display devices shall be no more than 34 inches (864 mm) above the floor...
-
11B-806.2.3.1 Personal lift device floor space
There shall be a clear space under the bed for the use of a personal lift device. The clear space shall extend under the bed parallel to the long side and be adjacent to an...