Specifications for benches address clear floor or ground space (903.2), size (903.3), back support (903.4), height (903.5), structural strength (903.6), and slip resistance in wet locations...
Search Results "Clear Opening"
Commonly Searched Documents
-
903 Benches
-
11B-805 Medical care and long-term care facilities
A 36-inch (914 mm) minimum wide clear space shall be provided along the full length of each side of beds, exam tables, procedure tables, gurneys and lounge chairs....
-
1134A.7 Water closets
The minimum floor space provided at a water closet shall be 48 inches (1219 mm) in clear width. ...
- Automatic Curtain Ltd. Remote Controlled Automatic Roller Shade System I
- Lighthouse International
-
Temporay Concert Accessibility
The question that has arisen about how to address access to the open ground area in front of the stage where patrons stand – they are thinking of laying down some “mats” that would provide...
-
Re: American Specialties 9014 Surface Mounted Horizontal Baby Changing Station
The strap was left dangling to use as an opener. ASI Technical Data Sheet shows it is compliant, but with the design of the handle it is not....
-
608.2.1 Transfer Type Shower Compartments
Transfer type shower compartments shall be 36 inches (915 mm) by 36 inches (915 mm) clear inside dimensions measured at the center points of opposing sides and shall have a 36 inch (915...
-
Handrails
If handrails are mounted on walls, the clear space between the handrail and wall must be 1.5 inches....
-
308.2.2 Obstructed High Reach
Where a high forward reach is over an obstruction, the clear floor space shall extend beneath the element for a distance not less than the required reach depth over the obstruction....
-
R212 Street Furniture (Section-by-Section Analysis)
At least 50 percent, but no less than one, of benches at each location must provide a clear space for a wheelchair adjacent to the bench. Benches at tables are not required to comply....
-
Adaptability
Rooms need to be designed to provide required clear floor space at fixtures, turning space, and door clearance....
-
On-Site Readers
Specific skills are needed to be an on-site reader: ability to read material well, a good clear voice, and, ideally, knowledge of the language and vocabulary used in the documents....
-
Escalators
Escalators must have a clear width of at least 32” and meet specific provisions in the ASME A17.1 Safety Code for Elevators and Escalators....
-
11B-904.4 Sales and service counters
the number of existing mail boxes, the counter shall be permitted to have a portion which is 24 inches (610 mm) long minimum complying with Section 11B-904.4.1 provided that the required clear...
-
11B-904.4 Sales and service counters
the number of existing mail boxes, the counter shall be permitted to have a portion which is 24 inches (610 mm) long minimum complying with Section 11B-904.4.1 provided that the required clear...
- Corbin Russwin Inc. FE6700 Storm Shutter Multi-Point Latching System
- Gamco Recessed Sanitary Napkin Disposal - ND-4
- Gamco Surface Mounted Coverall Sanitary Napkin Disposal - ND-5
-
Flush Controls On Toilets
As we all know the requirements for the accessible toilet flush control is on the wide, open side of the toilet room and/or compartment. ...
- Nana Wall Systems, Inc. Sliding Glass Walls With Solid Wood HSW66
-
11B-208.2 Minimum number
The term "parking facility" is used in Section 11B-208.2 instead of the term "parking lot" so that it is clear that both parking lots and parking structures are required to comply with this...
- Access to Independence of Cortland County, Inc. (ATI) - Cortland, NY