This dryer protrudes more than 4" from the wall and is greater than 27" above the finish floor. Isn't this a violation of Section 307 Protruding Objects?...
Search Results "Floor Identification"
Commonly Searched Documents
-
Section 307 Protruding Objects
-
11B-308.3.2 Obstructed high reach
Where a clear floor or ground space allows a parallel approach to an element and the high side reach is over an obstruction, the height of the obstruction shall be 34 inches (864 mm) maximum...
-
Notes
II The IDeA Center in its research defined wheelchair wheelbase as the distance from the center of the primary drive wheel to the center of the caster measured parallel to the floor....
-
IV. Program Access
., moving a public information office from the third floor to the first floor of a building....
-
11B-604.7 Dispensers and disposal units
The outlet of the dispenser shall be below the grab bar, 19 inches (483 mm) minimum above the finish floor and shall not be located behind grab bars....
- ASI Global Partitions Stainless Steel Toilet Partitions
- Pressalit Care Nursing bench 2000, electrically height adjustable
- Cybex Total Access Lat Pull Exercise Machine
- Mansfield Toilet ADA Commercial Package CP-1313
-
1115B.3.2, Item 3
.|_ On the other side of the water closet, provide a minimum of 28 inches (711 mm) wide clear floor space if the water closet is adjacent to a fixture or a minimum of 32 inches (813 mm)...
-
Addendum A: List of Terms
Transfer: a transfer that can be completed without the assistance or intervention Level Transfer- A transfer where the transfer surface is at the same height as the wheelchair seat to floor...
-
III-7.8400 Business and mercantile
The size of the store and the number of floors will be relevant factors in determining how many counters need to be accessible....
-
Clear Space Evaluation
nlike [sic] the first phase of the transfer study, subjects in this study were not impeded by any obstacles on the floor that limited the manner of which they approached the transfer station...
-
11B-202 Existing buildings and facilities
In no case shall the distance exceed 200 feet of travel or more than one floor above or below the area for access to staff toilets....
-
11B-407.2.2.1 Visible and audible signals
Where in-car signals are provided, they shall be visible from the floor area adjacent to the hall call buttons. Exceptions: 1. Reserved. 2. Reserved....
-
C. Food Service
.: direct counter service) at counters or bars, is there a minimum 60" long portion providing a 27" high knee space, at least 19" deep, with the counter top at 28"-34" above the floor, or...
-
4(6)
door to dwelling units with direct exterior access, outside landing surfaces constructed of impervious materials such as concrete, brick or flagstone, are no more than 1/2 inch below the floor...
-
H. Door Maneuvering Clearance
.: entry door, connecting room door, bathroom doors and other passage doors) in every accessible guestroom/suite, are there at least 18" of clear floor space on the latch side for persons...
-
1134A.8, Item 4.3
The clear floor space required by Item 2 shall not extend into the knee and toe space more than 19 inches (483 mm). (See Figure 11A-9D)....
-
11B-605.4 Flush controls
Hand operated flush controls shall comply with Section 11B-309 except that the flush control shall be mounted at a maximum height of 44 inches (1118 mm) above the finish floor....
-
3. Protruding Objects
Is the voting area free of objects that protrude from the side more than 4 inches into the route with the bottom of the object more than 27 inches above the floor?...
-
Site Constraints
An example might include construction of a new infill building with a historic facade which must be maintained (thus predetermining the entry floor level) and where space for a ramp is not...
-
Wheelchair Access
If phones are installed as single units, one per floor must be accessible....