Accessible routes shall consist of one or more of the following components: walking surfaces with a running slope not steeper than 1:20, doorways, ramps, curb ramps excluding the...
Search Results "Toilet Room Door"
-
402.2 Components
-
T502.2.2 Other Vehicles
For other non-rail vehicles, the vertical clearance at doorways shall be 56 inches (1420 mm) minimum on small non-rail vehicles and 68 inches (1725 mm) on large non-rail vehicles.
-
402.2 Components
402.2 Components. Accessible routes shall consist of one or more of the following components: walking surfaces with a running slope not steeper than 1:20, doorways, ramps, curb ramps...
-
10.3.1(7)*
(7)* Automatic fare vending, collection and adjustment (e.g., add-fare) systems shall comply with 4.34.2, 4.34.3, 4.34.4, and 4.34.5. At each accessible entrance such devices shall...
-
Accessible Routes [§402]
Accessible Routes [§402] Components of accessible routes include walking surfaces, doorways, ramps, curb ramps, elevators, and, where permitted, platform lifts.
-
11B-402.2 Components
Accessible routes shall consist of one or more of the following components: walking surfaces with a running slope not steeper than 1:20, doorways, ramps, curb ramps excluding the...
-
11B-402.2 Components
Accessible routes shall consist of one or more of the following components: walking surfaces with a running slope not steeper than 1:20, doorways, ramps, curb ramps excluding the...
- Hager Companies Round Pull 10
-
Section 36.403 Alterations: Path of Travel (Section-by-Section Analysis)
Section 36.403 Alterations: Path of Travel (Section-by-Section Analysis) In the NPRM, the Department proposed one change to Sec. 36.403 on alterations and path of travel by adding...
- Hager Companies Cast Pull 7N
-
Phones
TTYs at hotel front desks will allow guests using TTYs in their room to access in-house services....
-
Other Requirements in the ADA Standards
Automated Doors Maneuvering clearance is required on the egress side of automated doors unless they are equipped with standby power or they stay open in power-off mode (§404.3.2)...
- Hager Companies Cast Pull 5N
- Hager Companies Cast Pull 6N
-
F215.4 Transient Lodging
Guest rooms required to comply with F224.4 shall provide alarms complying with 702....
-
215.4 Transient Lodging
Guest rooms required to comply with 224.4 shall provide alarms complying with 702....
- CRL Push Button Center Locks for Glass Doors 08 4210
-
Bradley Diplomat Napkin/Tampon Vendor 4A20
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Nana Wall Systems, Inc. High Velocity Hurricane Zone Folding Glass Walls SL73
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Nana Wall Systems, Inc. Folding Glass Walls SL60
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Nana Wall Systems, Inc. Folding Glass Walls SL45
Requires the Premium User plan or above. (Login or upgrade your account!)
-
11B-809.10.6.3 Floor space
A clear maneuvering space 30 inches (762 mm) wide minimum by 48 inches (1219 mm) minimum in length shall be located outside the shower, with the width flush with the control wall and...
-
11B-809.10.6.3 Clearance
A clearance of 36 inches (914 mm) wide minimum by 48 inches (1219 mm) long minimum measured from the control wall shall be provided outside the shower as illustrated in Figure...
-
4.1.6(3)(e)(ii)
(ii) Where it is technically infeasible to install a required standard stall (Fig. 30(a)), or where other codes prohibit reduction of the fixture count (i.e., removal of a water...