length of the gangway or series of gangways serving as part of a required accessible route is 30 feet (9144 mm) minimum, gangways shall not be required to comply with Section 11B-405.2 _|Slope...
Search Results "Sloped Area"
-
11B-1005.1 Accessible routes
-
Gangways
Gangways A gangway is a variable-sloped pedestrian walkway linking a fixed structure or land with a floating structure....
-
1009.4.1 Clear Deck Space
A clear deck space of 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer wall....
-
§ 36.304(d)(3)
Such measures include, for example, providing a ramp with a steeper slope or widening a doorway to a narrower width than that mandated by the alterations requirements....
-
Verify Rough Plumbing
drain. 11B-607.5 Installation height and location of shower controls. 11B-608.5 Location of shower drains and floor slope...
-
R304.2.3 Flared Sides
Where a pedestrian circulation path crosses the curb ramp, flared sides shall be sloped 10 percent maximum, measured parallel to the curb line. Advisory R304.2.3 Flared Sides....
-
Thresholds at Doorways [4.13.8]
Thresholds above ¼ inch must be beveled with a slope no greater than 1:2....
-
Verify Rough Plumbing
drain. 11B-607.5 Installation height and location of shower controls. 11B-608.5 Location of shower drains and floor slope...
-
2) Where the Standard says "Changes in level are not permitted"
such as 304.2 for turning spaces: Here the standard is followed by an unenforceable advisory that says, "As used in this section, the phrase ‘changes in level’ refers to surfaces with slopes...
-
Is there a minimum distance between changes in level?
used to span vertical changes greater than ½”, must have level landings and clearances at the tops and bottoms of each run to provide adequate separation and resting intervals between sloping...
-
11B-303.3 Beveled
Changes in level between ¼ inch (6.4 mm) high minimum and ½ inch (12.7 mm) high maximum shall be beveled with a slope not steeper than 1:2....
-
11B-1005.1 Accessible routes
length of the gangway or series of gangways serving as part of a required accessible route is 30 feet (9144 mm) minimum, gangways shall not be required to comply with Section 11B-405.2 _|Slope...
- Q'Straint : On Board with the QUANTUM - Automatic Wheelchair Securement
-
Healthcare Stories - Frances Deloatch
Requires the Registered User plan or above. Login!
-
Transfer Height: ADA Standard Section 1002.5.2
The height of amusement ride seats designed for transfer shall be 14 inches (355 mm) minimum and 24 inches (610 mm) maximum measured from the surface of the load and unload area....
-
11B-246.8 Nature trails
Nature trails and similar educational and informational areas shall be accessible to individuals with vision impairments by the provision of rope guidelines, raised Arabic numerals and symbols...
-
11B-246.8 Nature trails
Nature trails and similar educational and informational areas shall be accessible to individuals with vision impairments by the provision of rope guidelines, raised Arabic numerals and symbols...
-
Primary Function
Areas that contain a primary function include, but are not limited to, the customer services lobby of a bank, the dining area of a cafeteria, the meeting rooms in a conference center, as...
-
§27.71(h)(3)(ii)
(ii) A service animal training organization, the airport, and the carriers in the terminal in which the relief area will be located agree that a relief area would be better placed outside...
-
Additions: ADA Standard Section 202.2
Section 202.2 covers the most current requirements for additions in existing building and facilities.
-
ACCESSIBILITY
[DSA-AC] Accessibility is the combination of various elements in a building, facility, site, or area, or portion thereof which allows access, circulation and the full use of the building...
-
11B-1002.6.3 Wheelchair storage space
Wheelchair storage spaces complying with Section 11B-305 shall be provided in or adjacent to unload areas for each required transfer device and shall not overlap any required means of egress...
-
11B-1002.6.3 Wheelchair storage space
Wheelchair storage spaces complying with Section 11B-305 shall be provided in or adjacent to unload areas for each required transfer device and shall not overlap any required means of egress...
-
ACCESSIBILITY
[DSA-AC] Accessibility is the combination of various elements in a building, facility, site, or area, or portion thereof which allows access, circulation and the full use of the building...