Platform boarding edges not protected by platform screens or guards shall have detectable warnings complying with Section 11B-705 along the full length of the public use area of the platform...
Search Results "Section 505"
-
11B-810.5.2 Detectable warnings
-
11B-227.1 General
Where provided, check-out aisles, sales counters, service counters, food service lines, queues, and waiting lines shall comply with Sections 11B-227 and 11B-904....
-
11B-406.3 Parallel curb ramps
Parallel curb ramps shall comply with Sections 11B-406.3 and 11B-406.5. A parallel curb ramp may be provided with one sloping segment or two opposing sloping segments....
-
11B-812.6.2 Standard accessible
Vehicle spaces serving standard accessible EVCS shall be 108 inches (2743 mm) wide minimum and shall have an adjacent access aisle complying with Section 11B-812.7....
-
11B-409.4.1 Inside dimensions of elevator cars
Elevator cars shall provide a clear floor space of 36 inches (914 mm) minimum by 48 inches (1219 mm) minimum and shall comply with Section 11B-305....
-
11B-802.1.1 Floor or ground surface
The floor or ground surface of wheelchair spaces shall comply with Section 11B-302. Changes in level, slopes exceeding 1:48, and detectable warnings shall not be permitted....
-
11B-206.4.2 Parking structure entrances
Where direct access is provided for pedestrians from a parking structure to a building or facility entrance, each direct access to the building or facility entrance shall comply with Section...
-
11B-246.1 General
Outdoor developed areas shall comply with Section 11B-246....
-
11B-1005.3 Edge protection
Where railings, guards, or handrails complying with Section 11B-1005.2 are provided, edge protection complying with Section 11B-1005.3.1 or 11B-1005.3.2 shall be provided....
-
11B-904.4.2 Forward approach
Knee and toe space complying with Section 11B-306 shall be provided under the counter....
-
11B-224.1.1 Alterations
Where guest rooms are altered or added, the requirements of Section 11B-224 shall apply only to the guest rooms being altered or added until the number of guest rooms complies with the minimum...
-
11B-224.1.1 Alterations
Where guest rooms are altered or added, the requirements of Section 11B-224 shall apply only to the guest rooms being altered or added until the number of guest rooms complies with the minimum...
-
11B-904.4.2 Forward approach
Knee and toe space complying with Section 11B-306 shall be provided under the counter....
-
11B-1005.3 Edge protection
Where railings, guards, or handrails complying with Section 11B-1005.2 are provided, edge protection complying with Section 11B-1005.3.1 or 11B-1005.3.2 shall be provided....
-
11B-246.1 General
Outdoor developed areas shall comply with Section 11B-246....
-
Plan 4B: 13-Foot Wide Accessible Guest Room
closet clearance (section 604.3). ...
-
Plan 6A: 12-Foot Wide Accessible Guest Room
The following accessible features are provided in the bathroom: • Comparable vanity counter top space (section 806); • Transfer shower (section 603.2); • Shower seat (section 610.3...
-
Plan 3B: 12-Foot Wide Accessible Guest Room
long (section 608.2.2); • Circular turning space in room (section 603.2.1); • Required clear floor spaces at fixtures and turning space overlap (section 603.2.2); • Turning space...
-
Plan 2A: 13-Foot Wide Accessible Guest Room
(section 608.2.2); • Circular turning space in room (section 603.2.1); • Required clear floor spaces at fixtures and turning space overlap (section 603.2.2); • Turning space includes...
-
Plan 2B: 13-Foot Wide Accessible Guest Room
closet clearance (section 604.3). ...
-
Plan 4A: 13-Foot Wide Accessible Guest Room
(section 604.5.2); • Circular turning space in room (section 603.2.1); • Required clear floor spaces at fixtures and turning space overlap (section 603.2.2); • Turning space includes...
-
Organization of this NPRM
Following the general issues section is the "Section-By-Section Analysis and Response to Comments." ...
-
Table of Contents
Elevators 410 Platform Lifts CHAPTER 5: GENERAL SITE AND BUILDING ELEMENTS 501 General 502 Parking Spaces 503 Passenger Loading Zones 504 Stairways 505...
-
11B-243.1 General
Where shooting facilities with firing positions are designed and constructed at a site, at least 5 percent, but no fewer than one, of each type of firing position shall comply with Section...