The total height of the toilet seat on the riser for a pit toilet shall be between 17 inches (430 mm) and 19 inches (485 mm) above the floor or ground surface....
Search Results "Extended Floor Surface"
Commonly Searched Documents
-
5.3.3.1 Height
-
220 Automatic Teller Machines and Fare Machines
Gates which must be pushed open by wheelchair or mobility aid users shall have a smooth continuous surface extending from 2 inches above the floor to 27 inches above the floor and shall...
-
1134A.5, Item 1
Floor space. ...
-
1134A.5, Item 1
Floor space....
-
11B-705.1.2.3 Islands or cut-through medians
Detectable warnings at pedestrian islands or cut-through medians shall be 36 inches (914 mm) minimum in depth extending the full width of the pedestrian path or cut-through less 2 inches...
-
11B-705.1.2.3 Islands or cut-through medians
Detectable warnings at pedestrian islands or cut-through medians shall be 36 inches (914 mm) minimum in depth extending the full width of the pedestrian path or cut-through less 2 inches...
-
Protrusions
Where a wheelchair space is located on a ride, nothing may protrude into the front of the wheelchair space 9 inches from the floor....
-
4(6)
(6) At the primary entry door to dwelling units with direct exterior access, outside landing surfaces constructed of impervious materials such as concrete, brick or flagstone, are no more...
-
308.2.2 Obstructed High Reach
Where a high forward reach is over an obstruction, the clear floor space shall extend beneath the element for a distance not less than the required reach depth over the obstruction....
-
610.2 Bathtub Seats
The top of bathtub seats shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum above the bathroom finish floor....
-
11B-904.4 Sales and service counters
The accessible portion of the counter top shall extend the same depth as the sales or service counter top....
-
11B-904.4 Sales and service counters
The accessible portion of the counter top shall extend the same depth as the sales or service counter top....
-
11B-904.4.2 Forward approach
A portion of the counter surface that is 36 inches (914 mm) long minimum and 34 inches (864 mm) high maximum shall be provided....
-
H11
If mirrors are provided, is the bottom of the reflecting surface for the mirror at this lavatory no higher than 40 inches above the floor or is a full length mirror provided?...
- Bobrick ConturaSeries Surface-Mounted Paper Towel Dispenser/Waste Receptacle with TowelMate and LinerMate B-43699
-
Technical Memorandum TM 2012-04 Multi-Story Buildings and Facilities
The term “story” is defined in 106.5.64 as that portion of a building or facility designed for human occupancy included between the upper surface of a floor or the upper surface of the floor...
-
410 Platform Lifts
Section 410 provides requirements for platform lifts and addresses floor surfaces, clear floor space, operable parts, and doors and gates....
-
M303.2.4.1.2 Height
Wheelchair spaces shall include toe clearance 9 inches (230 mm) high minimum above the floor measured to a depth of 6 inches (150 mm) maximum from the toe end of the wheelchair space....
-
2.3.2
For example, floor profilers can provide a very accurate measurement of surface flatness but are expensive and require training to use....
-
4.15.2* SPOUT HEIGHT
Spouts shall be no higher than 36 in (915 mm), measured from the floor or ground surfaces to the spout outlet (see Fig. 27(a))....
-
Is an accessible route required to rooftop levels?
., equipped with lighting, ventilation, and means of egress) that is “included between the upper surface of a floor and upper surface of the floor or roof next above” (§106.5)....
-
4.7.1 General
In alterations, where a condition for exception in section 1.1 prohibits full compliance with a specific requirement for clear floor or ground space surface, slope, size, or location, the...
-
Building Fire Alarm System: ADA Standard Section 809.5.1
Where a building fire alarm system is provided, the system wiring shall be extended to a point within the residential dwelling unit in the vicinity of the residential dwelling unit smoke...
-
11B-809.5.1 Building fire alarm system
Where a building fire alarm system is provided, the system wiring shall be extended to a point within the residential dwelling unit in the vicinity of the residential dwelling unit smoke...