Only a portion of the usable clear floor space can "count" as toe space, which is why a maximum depth and minimum height are specified for the front of the underlap of the required clear...
Search Results "Usable Door (FHA)"
-
Height and Clearances [4.19.2]
-
Section 4.1.6, Alterations (Section-By-Section Analysis and Response to Comments)
- Section 4.1.6, Alterations (Section-By-Section Analysis and Response to Comments) An alteration is a change to a building or facility that affects or could affect the usability of or...
-
Vertical Clearance [§307.4]
Vertical Clearance [§307.4] Headroom clearance of at least 80” high is required along all circulation paths (except at doors and doorways where a 78” minimum clearance is permitted to...
-
§ 38.57(b)
Particular attention shall be given to ensuring maximum maneuverability immediately inside doors. Ample vertical stanchions from ceiling to seat-back rails shall be provided....
-
Clear Floor Space [4.16.2]
Figure 28) specifies the amount of space required at an accessible toilet, not the minimum room size, which must also include turning space, clear floor space at other provided fixtures, door...
-
Program Accessibility
Programs, services, and activities, when “viewed in their entirety” must be readily accessible to and usable by people with disabilities. This is known as program accessibility....
-
Visual Alarms
Result: People who are deaf or hard of hearing cannot hear fire alarms, ringing telephones, knocking at doors or ringing doorbells....
-
DEFENDANTS’ RAISED PORCHES
At each of the 249 stores in question, two public entrances with doors that are not part of the porch flank the raised porch. ...
- Access to Independence of Cortland County, Inc. (ATI) - Cortland, NY
-
Head Room [4.3.5]
Eighty-inch doors, including those equipped with closers, are considered acceptable under this requirement....
-
Elevator Car Requirements [§407.4]
Alternative configurations that provide unobstructed wheelchair turning space (60” diameter circle or T-turn) with the doors closed are permitted....
-
§ 38.119(a)
(a) Any stepwell, or doorway with a lift, ramp or bridge plate, shall have, when the door is open, at least 2 foot-candles of illumination measured on the step tread, ramp, bridge plate...
-
§ 38.81(a)
(a) Any stepwell or doorway with a lift, ramp or bridge plate immediately adjacent to the driver shall have, when the door is open, at least 2 foot-candles of illumination measured on the...
-
11B-216.13.1 Use of Cleaner Air Symbol
Symbol complying with Section 11B-703.7.2.5 is permitted to be posted in compliance with Section 11B-216.3 to indicate rooms, facilities, and path of travels that are accessible to and usable...
-
12147(b)(2)(B) Extension for extraordinarily expensive structural changes
changes to, or replacement of, existing facilities; except that by the last day of the 20th year following July 26, 1990, at least 2/3 of such key stations must be readily accessible to and usable...
-
2.1 Parking
Are there usable ramps or curb cuts onto the sidewalks? How far away from the entrance is the accessible parking?...
-
Dispensers [4.16.6]
Dispensers must provide continuous paper flow; those that have separate sheets or that control delivery are prohibited because they require repetitive hand motion and pinching and are not as usable...
-
Are fire extinguishers required to comply with the ADA Standards?
(However, non-discrimination provisions in regulations issued under the ADA may be pertinent to the usability of equipment and furnishings by people with disabilities.)...
-
ADJUSTED CONSTRUCTION COST
The costs shall not be reduced by the value of components, assemblies, building equipment or construction not directly associated with accessibility or usability....
-
ADJUSTED CONSTRUCTION COST
The costs shall not be reduced by the value of components, assemblies, building equipment or construction not directly associated with accessibility or usability....
-
Accessible Route to Dumpster and Enclosure
The dumpster is typically on the property site, serves the retail store, is open-air, usually has a fence with gate or door(s), and is often across an internal driveway (although some configurations...
-
1011.4, Item 3
Each exit door that is required to comply with Section 1011.1, and that leads directly to a grade-level exterior exit by means of an exit enclosure or an exit passageway shall be identified...
-
Back Entry
to improve visual acuity Recessed area rug Grill in the fireplace for year round healthy cooking Automatic opener which can be operated by wheelchair users on a door...
-
1013.4, Item 3
Each exit door that is required to comply with Section 1013.1, and that leads directly to a grade-level exterior exit by means of an exit enclosure or an exit passageway shall be identified...