Measure running slope along the same lines of measurements as stated in Section 1.1.13 Although the F - number system can be used to measure surface flatness for smooth surfaces it requires...
Search Results "Standing Surface"
Commonly Searched Documents
-
1.1.16 Alternate measurement tools
-
M102.1 Defined Terms
The following terms are defined in the proposed standards: Enforcing authority, medical diagnostic equipment, operable parts, and transfer surface....
-
Section 35.151(i) Curb ramps (Section-by-Section Analysis)
Upon further consideration, however, the Department has concluded that the regulation should acknowledge that there are times when there are transitions from sidewalk to road surface that...
-
11B-1002.5 Amusement ride seats designed for transfer
Where possible, designers are encouraged to locate the ride seat no higher than 17 to 19 inches (430 to 485 mm) above the load and unload surface....
-
11B-1009.5.7 Grab bars
Where a grab bar is provided on each step, the tops of gripping surfaces shall be 4 inches (102 mm) minimum and 6 inches (152 mm) maximum above each step and transfer platform....
-
§ 38.159(c)(8) Handrails
grasp them from outside the vehicle while starting to board, and to continue to use them throughout the boarding process, and shall have the top between 30 inches (760 mm) above the ramp surface...
-
11B-1002.5 Amusement ride seats designed for transfer
Where possible, designers are encouraged to locate the ride seat no higher than 17 to 19 inches (430 to 485 mm) above the load and unload surface....
-
11B-705.1.1.2 Dome spacing
Truncated domes in a detectable warning surface shall have a center-to-center spacing of 2.3 inches (58 mm) minimum and 2.4 inches (61 mm) maximum, and a base-to-base spacing of 0.65 inch...
-
11B-1009.5.7 Grab bars
Where a grab bar is provided on each step, the tops of gripping surfaces shall be 4 inches (102 mm) minimum and 6 inches (152 mm) maximum above each step and transfer platform....
-
Summary of the project
Summary of the project Throughout the course of the project representatives from various trade organizations that represent the following materials that may be used for exterior surfaces...
-
1134A.6, Item 2
The floor surfaces shall be of Carborundum or grit-faced tile or of material providing equivalent slip resistance....
-
T405.3 Visual Contrast
The stripe shall be 1 inch (25 mm) wide minimum and shall contrast visually with the rest of the step tread or circulation path surface either light-on-dark or dark-on-light....
-
R405.3.4 Clearance Reduction
Between 230 mm (9 in) and 685 mm (2.25 ft) above the finish surface, the knee clearance shall be permitted to reduce at a rate of 25 mm (1 in) in depth for each 150 mm (6 in) in height....
-
6.10 Openings
Openings in the surface of beach access routes and their related resting intervals may be up to 1/2 inch (13 millimeters) wide....
-
1134A.6, Item 2
The floor surfaces shall be of Carborundum or grit-faced tile or of material providing equivalent slip resistance....
-
11B-809.10.6.2 Slope
The floor surfaces shall be of Carborundum, grit-faced tile or of material providing equivalent slip resistance....
-
Areas of Sport Activities
Areas of sport activities must comply with all ADAAG requirements, except that they are exempt from the requirement that surfaces must be stable, firm, and slip resistant, and from the restrictions...
-
1012.3 Opening limitations
From a height of 34 inches (864 mm) to 42 inches (1067 mm) above the adjacent walking surfaces, a sphere 8 inches (203 mm) in diameter shall not pass....
-
Gangway Slope and Rise Exceptions
For example, if the vertical distance between where the gangway departs the landside connection and the elevation of the pier surface at the lowest water level is 10 feet, the gangway would...
-
11B-502.6 Identification
Signs shall be 60 inches (1524 mm) minimum above the finish floor or ground surface measured to the bottom of the sign. [2010 ADAS] 502.6 Identification. ...
-
T303 Handrails, Stanchions, and Handholds
., space between gripping surface and adjacent surface)....
-
11B-502.6 Identification
Signs shall be 60 inches (1524 mm) minimum above the finish floor or ground surface measured to the bottom of the sign. [2010 ADAS] 502.6 Identification. ...
-
11B-502.6 Identification
Signs shall be 60 inches (1524 mm) minimum above the finish floor or ground surface measured to the bottom of the sign. [2010 ADA Standards] 502.6 Identification....
-
Dispensers: ADA Standard Section 604.7
Section 604.7 covers the current ADA Standards for toilet paper dispensers.