Problem Two (Protruding Objects)
Problem Two: A wall-mounted display case protrudes seven inches from the wall and the bottom of the case is 40 inches above the floor....
-
M. Reach Range
Are the rod and shelf in the clothes closet or wall mounted unit within 54" of the floor for side approach or 48" of the floor for forward approach so persons who use wheelchairs can approach...
-
Size: ADA Standard Section 604.8.1.1
Section 604.8.1.1 covers the current ADA Standards for the size of wheelchair accessible compartments.
-
1007.2.1 Elevators required
In buildings where a required accessible floor is four or more stories above or below a level of exit discharge, at least one required accessible means of egress shall be an elevator complying...
-
Elevator Operable Parts
The proposed rule specified that call buttons be located 35 to 48 inches above the floor (407.2.2)....
-
A4.1.3(10)
A4.1.3(10) If an odd number of drinking fountains is provided on a floor, the requirement in 4.1.3(10)(b) may be met by rounding down the odd number to an even number and calculating 50%...
-
F204.1 General
Within play areas, protruding objects on circulation paths shall not be required to comply with 307 provided that ground level accessible routes provide vertical clearance in compliance...
-
8. Service Animals
.: restaurants, bar areas, facility grounds, vans/shuttle buses, and other areas for meeting or recreation)?...
-
204.1 General
Within play areas, protruding objects on circulation paths shall not be required to comply with 307 provided that ground level accessible routes provide vertical clearance in compliance...
- DORMA BTS75V SERIES DOOR CLOSER
-
711.4.1 Through penetrations
Exceptions: Penetrations by steel, ferrous or copper conduits, pipes, tubes, vents, concrete, or masonry through a single fire-resistance-rated floor assembly where the annular...
-
g-iii
Is there clear maneuvering floor space in front of each accessible door (see ADA Standards § Fig. 25) and, on the pull side, is there at least 18 inches clear floor space beyond the latch...
-
E2-2. Overhead Objects
Are pedestrian routes leading to or serving the voting area free of overhead objects with the bottom edge lower than 80 inches above the floor?...
-
5.7.1 Lift Compatibility Clearance in Base for M301
5.7.1 Lift Compatibility Clearance in Base for M301 Description: For portable floor lifts to be effective, they must deploy at diagnostic equipment such that the boom of the lifts can...
-
Orientation (slide 12)
Floor-plan organization, if it’s consistent from floor to floor, it’s much easier for people to navigate....
-
§ 38.83(c)(5) Slope
If the height of the vehicle floor, under 50% passenger load, from which the ramp is deployed is 3 inches or less above the station platform a maximum slope of 1:4 is permitted; if the height...
-
11B-604.7.1 Dispensers
The outlet of the dispenser shall be below the grab bar, 19 inches (483 mm) minimum above the finish floor and shall not be located behind grab bars....
-
11B-809.9.3 Removable base cabinets
sinks and work surfaces provided that all of the following conditions are met: a) base cabinets can be removed without the use of specialized tools or knowledge; b) the finish floor...
-
11B-809.9.3 Removable base cabinets
sinks and work surfaces provided that all of the following conditions are met: a) base cabinets can be removed without the use of specialized tools or knowledge; b) the finish floor...
-
11B-604.7.1 Dispensers
The outlet of the dispenser shall be below the grab bar, 19 inches (483 mm) minimum above the finish floor and shall not be located behind grab bars....