The space shall be 36 inches (914 mm) wide minimum and shall extend forward 48 inches (1219 mm) minimum from a line located 12 inches (305 mm) behind the rear edge of the seat....
Search Results "Distinct Viewing Location"
-
11B-1009.2.3 Clear deck space
-
11B-1009.2.3 Clear deck space
The space shall be 36 inches (914 mm) wide minimum and shall extend forward 48 inches (1219 mm) minimum from a line located 12 inches (305 mm) behind the rear edge of the seat....
-
11B-809.9.1 Clear floor space
floor spaces 30 inches (762 mm) by 48 inches (1219 mm), with centerlines aligned with the centerline of the work surface, appliance, sink or fixture, shall be provided in the following locations...
-
11B-809.9.4 Work surfaces
Work surfaces shall be 36 inches (914 mm) maximum above the finish floor with minimum lengths at the following locations as required by this section: Linear length of 30 inches...
-
11B-703.7.2.6.1 Men’s toilet and bathing facilities
An equilateral triangle, ¼ inch (6.4 mm) thick with edges 12 inches (305 mm) long and a vertex pointing upward, shall be located at entrances to men’s toilet and bathing facilities....
-
Section 35.151(g)(2)
In the NPRM, the Department proposed Sec. 35.151(g)(2) which prohibits wheelchair spaces and companion seating locations from being “located on, (or obstructed by) temporary platforms or...
-
Contrast
The proposed rule specified that detectable warnings in interior locations differ from adjoining walking surfaces in resiliency or sound-on-cane contact (705.2.3)....
-
Two-Way Communication
Comments recommended that the guidelines address emergency communication systems located in a closed compartment and apply the specifications for operable parts in section 309 to compartment...
-
Benches
If the bench is not located next to a wall, the bench must have back support that is 42 inches minimum in length and extends from a point 2 inches maximum above the seat to a point 18 inches...
-
F240.1.1 Additions
When the second phase is completed, at least 10 elevated play components must be located on an accessible route, and at least 7 ground level play components, including 4 different types,...
-
Data Analysis
For example, the area measurement depends on two variables that cannot be analyzed separately: the amount of space occupied by the physical dimensions of the WMD user and the actual location...
-
F) Library Services
may have a facility that is difficult to make accessible or lack the resources to make essential physical changes may choose to offer the programs and services in an alternate accessible location...
-
240.1.1 Additions
When the second phase is completed, at least 10 elevated play components must be located on an accessible route, and at least 7 ground level play components, including 4 different types,...
-
5.1 Public Notification of Availability
This notification should be of the same order of visibility and location as information regarding other attributes of a performance ("Dolby Sound", etc.)....
-
1.1.14 Flatness of ramp cross slope
In addition to the measurement locations in 1.1.14, if a portion of the ramp appears to be steeper than 1:48 (approximately 2%) measure at that location as well....
-
11B-406.5.10 Diagonal curb ramps
Diagonal curb ramps with flared sides shall have a segment of curb 24 inches (610 mm) long minimum located on each side of the curb ramp and within the marked crossing....
-
3. New Construction vs. Alterations
When highways, streets, and roads are built or altered post-ADA, they must have curb ramps at certain locations....
-
Water Hydrants
Locate water spouts between 28 inches (710 millimeters) and 36 inches (915 millimeters) above the ground or floor surface on the edge of a clear space that is at least 72 inches (1,830 millimeters...
-
Transfer Sides (M301.2.3 and M302.2.3)
M301.2.3 and M302.2.3 would require the transfer surface to be located so as to provide patients who use mobility devices the option to transfer onto the short side and the long side of...
-
Re: 206.2.5 Restaurants and Cafeterias
This code applies to fixed or built-in elements of buildings, structures, site improvements and pedestrian routes or vehicular ways located on a site....
-
Enplaning, Deplaning, and Connecting Assistance
The Foreign Carriers NPRM built on this existing requirement, proposing to require carrier assistance between the terminal entrance and gate, as well with accessing ticket and baggage locations...
-
Issue: Program Accessibility
Requirement: Title II requires city governments to ensure that all of their programs, services, and activities, when viewed in their entirety, are accessible to people with disabilities...
-
36 CFR Part 1191 ADA and ABA Accessibility Guidelines for Emergency Transportable Housing Units
You need JavaScript enabled to view it....
-
Web / HTML implementation
You can view an HTML page with the images showing, and all of the alt-text next to each image....