In residential facilities, an accessible route shall not be required to connect stories where residential dwelling units with mobility features required to comply with 809.2 through 809.4...
Search Results "Accessibility Requirement"
-
206.2.3 Multi-Story Buildings and Facilities
-
2.3 Restrooms
Are the restrooms accessible? Is the entry door at least 32 inches wide?...
- Access Board: Bathtubs
-
14 CFR Part 382 Nondiscrimination on the Basis of Disability in Air Travel (Air Carrier Access Act) (with amendments issued through May 2016)
U.S. Department of Transportation 14 CFR Part 382 Nondiscrimination on the Basis of Disability in Air...
-
Required Means of Egress [IBC §1007.1 (2003), §1003.2.13 (2000)]
The IBC requirements for accessible means of egress apply to new construction; accessible means of egress are not required to be added in alterations to existing facilities....
- The GRIT Freedom Chair in soft sand
-
Re: DSA Drawing 11B-406-1C Curb Ramp Adjoining a Parking Access Aisle next to a Curb and Gutter (2016 CBC)
This drawing should show that the gutter is not included in the required min 18’ depth. The dashed lines don’t spell it out clearly enough to me....
-
1018.4 Clear Width
This section requires the clear width of beach access routes to be 60 inches minimum to enable individuals who use wheeled mobility devices to pass beach visitors traveling in the opposite...
-
11B-233.3.4.2 Alterations to individual residential dwelling units
Residential dwelling units required to comply with Sections 11B-233.3.1.1 and 11B-233.3.1.2 shall be on an accessible route as required by Section 11B-206....
- Acoustiguide Custom Multimedia Content Application
-
11B-502.6.4.1
The parking space shall be marked with an International Symbol of Accessibility complying with Section 11B-703.7.2.1 in white on a blue background a minimum 36 inches wide by 36 inches high...
-
11B-502.6.4.1
The parking space shall be marked with an International Symbol of Accessibility complying with Section 11B-703.7.2.1 in white on a blue background a minimum 36 inches wide by 36 inches high...
- San Francisco: Accessible Business Entrance Program
-
ADA Facilities Compliance Risk Assessment Form
Design Contract specifically requires design professionals to comply with the ADA and ADA Accessibility Guidelines. ____ (Y=2 pts.) 2.)...
-
11B-502.6.4.1
11B-502.6.4.1 The parking space shall be marked with an International Symbol of Accessibility complying with Section 11B-703.7.2.1 in white on a blue background a minimum 36 inches wide...
-
1193.33(c) (Advisory Guidance)
This paragraph requires manufacturers to consider including information on accessibility in training a manufacturer provides to its staff....
-
1007.8 Two-way communication
A two-way communication system shall be provided at the elevator landing on each accessible floor that is one or more stories above or below the story of exit discharge complying with Sections...
-
6.5 Surface
The surface of beach access routes and their related resting intervals shall be firm and stable....
-
11B-812.9 Surface marking
EVCS vehicle spaces shall provide surface marking stating “EV CHARGING ONLY” in letters 12 inches (305 mm) high minimum. The centerline of the text shall be a maximum of 6 inches...
-
11B-812.9 Surface marking
EVCS vehicle spaces shall provide surface marking stating “EV CHARGING ONLY” in letters 12 inches (305 mm) high minimum. The centerline of the text shall be a maximum of 6 inches...
-
11B-228.3 Electric vehicle charging stations
[See subsections ...]
-
11B-228.3 Electric vehicle charging stations
[See subsections ...]
- Hussey Seating Company In-Fill Decks
-
11B-1002.4.6 Approach
One side of the wheelchair space shall adjoin an accessible route when in the load and unload position....