Telephones shall be served by an electrical outlet complying with 309 located within 48 inches (1220 mm) of the telephone to facilitate the use of a TTY....
Search Results "Wheelchair Location"
-
Notification Devices: ADA Standard Section 806.3.2
-
11B-505.5 Clearance
Handrails may be located in a recess if the recess is 3 inches (76 mm) maximum deep and 18 inches (457 mm) minimum clear above the top of the handrail....
-
603.4 Coat Hooks and Shelves
Coat hooks shall be located within one of the reach ranges specified in 308....
-
606.1 General
If soap and towel dispensers are provided, they must be located within the reach ranges specified in 308....
- Takeform Fusion Signage Floor Directional Type B.2
-
Curb Ramps at Marked Crossings and Vehicular Lanes
Section 406.5 specifies the location of curb ramps at marked crossings....
-
Building Entrance
At least one door at the accessible entrance must have a minimum clear width of 32 inches for a voter who uses a wheelchair or other mobility device to pass through the doorway....
-
Ambulatory Accessible Compartment
The proposed rule referred to ambulatory accessible compartments as "non-wheelchair accessible" compartments....
-
1004.1 Clear Floor Space
Exercise machines and equipment shall have a clear floor space complying with 305 positioned for transfer or for use by an individual seated in a wheelchair....
-
9. Exterior Ramps
features: a. top and bottom landings that are level, at least as wide as the ramp they serve, and at least 60" long to allow for adequate maneuvering and resting space for persons who use wheelchairs...
-
Example of a Single-User Bathroom (with Roll-in Shower)
Since wheelchair access precludes curbs at roll-in showers, the shower area and clear floor space can be used for turning....
-
Bathroom Accommodating Reduced Ambulatory Mobility
“Comfort” height is easily used by tall people, wheelchair users, or older people with reduced upper body strength....
-
Kitchen Cabinets
With a remodel, they can be lowered to 32” a.f.f. for wheelchair users 10” removable drawer in the kick space to lower the cabinets for wheelchair users Self-closing drawers...
-
3) Where the standard says "Changes in level are not permitted", but no advisory follows the standard
changes in level that do not exceed those permitted in section 303.3 are acceptable in "required clear floor and ground spaces, turning spaces, and in similar spaces where people using wheelchairs...
-
COMPARISON OF OBJECTIVE MEASURES AND ENERGY COSTS
There was a strong, second order polynomial relationship between the Rotational Penetrometer stability measurements and the average energy cost for wheelchair users....
-
3.3.15.3 Side (lateral) reach – over an obstruction depth of 610 mm
.), only 31% of the manual wheelchair users, 24% of the power wheelchair users and 13% of the scooter users could reach 610 mm (24 in.) beyond the most lateral point of the WhMD....
-
The SmartWheel
The SmartWheel is a wheelchair - mounted device for measuring propulsion parameters that can be used to compute forces, acceleration, rate of rise, velocity, stroke length, and other aspects...
-
1134A.4 Sufficient maneuvering space
Bathing and toilet facilities required to be adaptable shall provide sufficient maneuvering space for a person using a wheelchair or other mobility aid to enter and close the door, use the...
-
1134A.4 Sufficient maneuvering space
Bathing and toilet facilities required to be adaptable shall provide sufficient maneuvering space for a person using a wheelchair or other mobility aid to enter and close the door, use the...
-
1004.1 Clear Floor Space
Exercise machines and equipment shall have a clear floor space complying with 305 positioned for transfer or for use by an individual seated in a wheelchair....
-
Maneuvering Space in Load and Unload Areas
Sections 234.2 and 1002.3 of the 2010 Standards require that a level wheelchair turning space be provided at the load and unload areas of each amusement ride....
-
PERSONAL DEVICES AND SERVICES {35.135}
PERSONAL DEVICES AND SERVICES {35.135} Types not required to be provided by public entity: Wheelchairs Individually prescribed devices, such as:...
-
29.1 Q. Is it acceptable to design a bathroom with an in-swinging 2'10 door which can be retrofitted to swing out in order to provide the necessary clear floor space in the bathroom?
Thus, for a bathroom, there must be sufficient maneuvering space and clear floor space so that a person using a wheelchair or other mobility aid can enter and close the door, use the fixtures...
-
1i
Are all of the small showers free of curbs or lips greater than 1/2" high at the shower floor that would impede wheelchair approach and transfer onto the folding shower seat?...