Where templates are provided, templates allowing content creation that conforms to all Level A and Level AA Success Criteria and all Conformance Requirements in WCAG 2.0...
Search Results "TAS: Texas Accessibility Standards"
Commonly Searched Documents
-
504.4 Templates
-
2.10.2 Gate Hardware
Gate hardware shall comply with operable controls requirements in ABAAS section 309.4 and 404.2.7.
-
2.4.1.3
A grade of up to 1:10 (10 percent) is permitted for up to 30 feet (9 m) of an ORAR. Resting intervals complying with section 2.3 shall be provided at distances of no more than 30...
-
A4.3.1 GENERAL
[See subsections ...]
-
1018.7.2 Cross Slope
The cross slope shall not be steeper than 1:48. EXCEPTION: Where the surface is other than concrete, asphalt, or boards, cross slopes not steeper than 1:20 shall be permitted when...
-
2.4.1.1
The running slope (grade) of an ORAR shall be 1:20 (5 percent) or less for any distance.
-
11B-401 General
[See subsections ...]
-
SECTION 1.9 DIVISION OF THE STATE ARCHITECT
[See subsections ...]
-
§ 37.61 Public transportation programs and activities in existing facilities
[See subsections ...]
-
11B-401 General
[See subsections ...]
-
SECTION 1.9 DIVISION OF THE STATE ARCHITECT
[See subsections ...]
-
Standard Roll-In Type Shower Compartments: ADA Standard Section 608.5.2
Section 608.5.2 covers the current ADA Standards for controls in standard roll-in type shower compartments.
-
Questions to Ask for Identifying Communication and Accommodation Needs
sell the contents for profit Notify June Kailes of use: jik@pacbell.net 1 Adapted and updated from: INFORMATION FOR ALL - ENSURING ACCESS...
-
Time periods
Time Periods Paragraphs (c) and (d) establish time periods for complying with the program accessibility requirement....
- Web Accessibility 101: Dragon NaturallySpeaking Demonstration Video
-
Expanding Your Market: Accessible Customer Service Practices for Hotel and Lodging Guests with Disabilities
U.S. Department of Justice Civil Rights Division Disability Rights Section
-
1016.1 General
This section contains the technical requirements for outdoor recreation access routes....
-
604.9.1 Location
maximum from the side wall or partition, except that the water closet shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum from the side wall or partition in the ambulatory accessible...
-
604.9.1 Location
maximum from the side wall or partition, except that the water closet shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum from the side wall or partition in the ambulatory accessible...
-
604.9.1 Location
maximum from the side wall or partition, except that the water closet shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum from the side wall or partition in the ambulatory accessible...
-
11B-604.9.1 Location
maximum from the side wall or partition, except that the water closet shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum from the side wall or partition in the ambulatory accessible...
-
11B-604.9.1 Location
maximum from the side wall or partition, except that the water closet shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum from the side wall or partition in the ambulatory accessible...
-
11B-203.9 Employee workstations
Employee workstations shall be on an accessible route complying with Division 4....