Required clear floor spaces, clearance at fixtures, and turning space shall be permitted to overlap....
Search Results "Turning T"
Commonly Searched Documents
-
11B-813.2.9 Overlap
-
1016.4 Passing Spaces
Passing spaces are required to be: A space 60 inches minimum by 60 inches minimum; or The intersection of two outdoor recreation access routes providing a T-shaped space...
-
6.3(2)
(2) Each bedroom shall have adequate space to provide a maneuvering space that complies with 4.2.3. In rooms with 2 beds, it is preferable that this space be located between beds.
-
6.3(4)
(4) Each four-bed room shall have a minimum clear floor space of 48 in (1220 mm) from the foot of the bed to the foot of the opposing bed; 36 in (915 mm) between the side of the bed...
-
Resting Intervals [1017.8]
A turning space that complies with section 304.3.2 of the ABA Standards must be provided....
-
1016.8 Resting Intervals
This section contains the technical requirements for the length (1016.8.1), width (1016.8.2), and slope (1016.8.3) of resting intervals; and for a turning space (1016.8.4) where resting...
-
Saunas and Steam Rooms
The wheelchair turning space in the sauna or steam room must comply with ADAAG, except that it can be obstructed by readily removable seats....
-
2) Where the Standard says "Changes in level are not permitted"
2) Where the Standard says "Changes in level are not permitted", such as 304.2 for turning spaces: Here the standard is followed by an unenforceable advisory that says, "As used in this...
-
Ground Surfaces: ADA Standard Section 1008.2.6
Ground surfaces on accessible routes, clear floor or ground spaces, and turning spaces shall comply with 1008.2.6. Advisory 1008.2.6 Ground Surfaces....
-
Miscellaneous - Areas of Sports Activities, Team or Player Seating, Exercise Machines & Equipment, Bowling Lanes, Saunas & Steam Rooms, and Shooting Facilities
Word Fillable Form (0.7MB) Word Non-Fillable Form (0.6MB) PDF Non-Fillable Form (0.6MB)
-
Clear Floor Space [4.35.2]
Space is important so that users can turn around and exit through swinging or sliding doors. Benches can overlap turning space where clearance (9 inches minimum) is available for toes....
- Boost Your Business - Chapter 10 - Restroom Fixtures
-
R304.5.3 Cross Slope
The cross slope of curb ramps, blended transitions, and turning spaces shall be 2 percent maximum....
-
304.2 Floor or Ground Surfaces
Floor or ground surfaces of a turning space shall comply with 302. Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted....
-
304.2 Floor or Ground Surfaces
Floor or ground surfaces of a turning space shall comply with 302. Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted....
-
11B-304.2 Floor or Ground Surfaces
Floor or ground surfaces of a turning space shall comply with Section 11B-302. Changes in level are not permitted. Exception: Slopes not steeper than 1:48 shall be permitted....
-
304.2 Floor or Ground Surfaces
Floor or ground surfaces of a turning space shall comply with 302. Changes in level are not permitted....
-
11B-304.2 Floor or Ground Surfaces
Floor or ground surfaces of a turning space shall comply with Section 11B-302. Changes in level are not permitted. Exception: Slopes not steeper than 1:48 shall be permitted....
-
2. a. iv. Path-of-Travel (wheelchair) space allowances
If a 180° turn is needed to exit an area, then a 60” diameter turning space or a 36” wide "T" is needed (see Figure 11)....
-
11B-304.2 Floor or ground surfaces
Floor or ground surfaces of a turning space shall comply with Section 11B-302. Changes in level, slopes exceeding 1:48, and detectable warnings shall not be permitted....
-
Doors [4.35.3]
Doors cannot swing into the turning space (as allowed in toilet and bathrooms because they are larger)....
-
11B-705.1.2.2.2.1 One entrance/exit point
Where the turning space has one entrance/exit point other than the sloped ramp segments, detectable warnings shall be 36 inches (914 mm) deep, as measured perpendicular to the curb, and...
-
5.3.2.3 Slope
The slope of the turning space and clear floor or ground space surface shall not be steeper than 1:48 (2 percent) in all directions....