703.5.5 Character Height. Minimum character height shall comply with Table 703.5.5. Viewing distance shall be measured as the horizontal distance between the character and an...
Search Results "Signage"
-
703.5.5 Character Height
-
703.5.6 Height from Finish Floor or Ground
703.5.6 Height from Finish Floor or Ground. Visual characters shall be 40 inches (1015 mm) minimum above the finish floor or ground. EXCEPTION: Visual characters indicating...
-
703.5.7 Stroke Thickness
703.5.7 Stroke Thickness. Stroke thickness of the uppercase letter "I" shall be 10 percent minimum and 30 percent maximum of the height of the character.
-
703.5.8 Character Spacing
703.5.8 Character Spacing. Character spacing shall be measured between the two closest points of adjacent characters, excluding word spaces. Spacing between individual characters...
-
703.5.9 Line Spacing
703.5.9 Line Spacing. Spacing between the baselines of separate lines of characters within a message shall be 135 percent minimum and 170 percent maximum of the character height.
-
703.6 Pictograms
703.6 Pictograms. Pictograms shall comply with 703.6.
-
703.6.1 Pictogram Field
703.6.1 Pictogram Field. Pictograms shall have a field height of 6 inches (150 mm) minimum. Characters and braille shall not be located in the pictogram field. Figure...
-
703.6.2 Finish and Contrast
703.6.2 Finish and Contrast. Pictograms and their field shall have a non-glare finish. Pictograms shall contrast with their field with either a light pictogram on a dark field or a...
-
703.6.3 Text Descriptors
703.6.3 Text Descriptors. Pictograms shall have text descriptors located directly below the pictogram field. Text descriptors shall comply with 703.2, 703.3 and 703.4.
-
703.7 Symbols of Accessibility
703.7 Symbols of Accessibility. Symbols of accessibility shall comply with 703.7.
-
703.7.1 Finish and Contrast
703.7.1 Finish and Contrast. Symbols of accessibility and their background shall have a non-glare finish. Symbols of accessibility shall contrast with their background with either a...
-
703.7.2 Symbols
703.7.2 Symbols.
-
703.7.2.1 International Symbol of Accessibility
703.7.2.1 International Symbol of Accessibility. The International Symbol of Accessibility shall comply with Figure 703.7.2.1. Figure 703.7.2.1 International Symbol of...
-
703.7.2.2 International Symbol of TTY
703.7.2.2 International Symbol of TTY. The International Symbol of TTY shall comply with Figure 703.7.2.2. Figure 703.7.2.2 International Symbol of TTY
-
703.7.2.3 Volume Control Telephones
703.7.2.3 Volume Control Telephones. Telephones with a volume control shall be identified by a pictogram of a telephone handset with radiating sound waves on a square field such as...
-
703.7.2.4 Assistive Listening Systems
703.7.2.4 Assistive Listening Systems. Assistive listening systems shall be identified by the International Symbol of Access for Hearing Loss complying with Figure...
-
III- 7.4400 Signage
III- 7.4400 Signage (ADAAG §4.1.2(7)). Requirements for exterior signs are essentially the same as those for interior signs (see §4.1.3(b) below)....
-
III-7.5165 Signage
III−7.5165 Signage (ADAAG §§4.1.3(16); 4.30.7)....
-
Hoistway Signs: ADA Standard Section 407.2.3
Section 407.2.3 covers the current ADA Standards for elevator hoistway signs.
-
Hoistway Signs: ADA Standard Section 408.2.3
Section 408.2.3: covers the current ADA Standards for limited-use/limited-application elevator hoistway signs.
-
810.4 Bus Signs
Bus route identification signs shall comply with 703.5.1 through 703.5.4, and 703.5.7 and 703.5.8. In addition, to the maximum extent practicable, bus route identification signs...
-
810.6 Rail Station Signs
Rail station signs shall comply with 810.6. EXCEPTION. Signs shall not be required to comply with 810.6.1 and 810.6.2 where audible signs are remotely transmitted to hand-held...