In residential dwelling units, the height of water closets shall be permitted to be 15 inches (380 mm) minimum and 19 inches (485 mm) maximum above the finish floor measured to the top of...
Search Results "Residential Dwelling Unit"
-
604.4 Seats
-
604.5 Grab Bars
In residential dwelling units, grab bars shall not be required to be installed in toilet or bathrooms provided that reinforcement has been installed in walls and located so as to permit...
-
606.2 Clear Floor Space
In residential dwelling units, cabinetry shall be permitted under lavatories and kitchen sinks provided that all of the following conditions are met: (a) the cabinetry can be removed...
-
606.3 Height
In residential dwelling unit kitchens, sinks that are adjustable to variable heights, 29 inches (735 mm) minimum and 36 inches (915 mm) maximum, shall be permitted where rough-in plumbing...
-
607.4 Grab Bars
In residential dwelling units, grab bars shall not be required to be installed in bathtubs located in bathing facilities provided that reinforcement has been installed in walls and located...
-
608.3 Grab Bars
In residential dwelling units, grab bars shall not be required to be installed in showers located in bathing facilities provided that reinforcement has been installed in walls and located...
-
608.4 Seats
EXCEPTION: In residential dwelling units, seats shall not be required in transfer type shower compartments provided that reinforcement has been installed in walls so as to permit the installation...
-
708.4 Residential Dwelling Unit Communication Systems
708.4 Residential Dwelling Unit Communication Systems. Communications systems between a residential dwelling unit and a site, building, or floor entrance shall comply with 708.4....
-
708.4.1 Common Use or Public Use System Interface
The common use or public use system interface shall include the capability of supporting voice and TTY communication with the residential dwelling unit interface....
-
708.4.2 Residential Dwelling Unit Interface
708.4.2 Residential Dwelling Unit Interface....
-
809 Residential Dwelling Units
-
809.1 General
Residential dwelling units required to provide mobility features shall comply with 809.2 through 809.4....
-
General: ADA Standard Section 409.1
Section 409.1 of the ADA Standards covers information in the current ADA Standards for private residence elevators.
-
809.2 Accessible Routes
Accessible routes complying with Chapter 4 shall be provided within residential dwelling units in accordance with 809.2....
-
809.2.1 Location
At least one accessible route shall connect all spaces and elements which are a part of the residential dwelling unit....
-
809.2.2 Turning Space
All rooms served by an accessible route shall provide a turning space complying with 304. EXCEPTION: Turning space shall not be required in exterior spaces 30 inches (760 mm)...
-
809.3 Kitchen
Where a kitchen is provided, it shall comply with 804.
-
809.4 Toilet Facilities and Bathing Facilities
dwelling unit....
-
809.5 Residential Dwelling Units with Communication Features
Residential dwelling units required to provide communication features shall comply with 809.5....
-
809.5.1 Building Fire Alarm System
Where a building fire alarm system is provided, the system wiring shall be extended to a point within the residential dwelling unit in the vicinity of the residential dwelling unit smoke...
-
809.5.1.1 Alarm Appliances
Where alarm appliances are provided within a residential dwelling unit as part of the building fire alarm system, they shall comply with 702....
-
809.5.1.2 Activation
All visible alarm appliances provided within the residential dwelling unit for building fire alarm notification shall be activated upon activation of the building fire alarm in the portion...
-
809.5.2 Residential Dwelling Unit Smoke Detection System
Residential dwelling unit smoke detection systems shall comply with NFPA 72 (1999 or 2002 edition) (incorporated by reference, see "Referenced Standards" in Chapter 1)....
-
809.5.2.1 Activation
All visible alarm appliances provided within the residential dwelling unit for smoke detection notification shall be activated upon smoke detection....